Hydraulic Fluid Controls 308395D
Regulates hydraulic pressure and flow when used with Graco’s Dyna-Star™ and Power-Star™ hydraulic-powered lubricant pumps. For professional use only.
Used with Dyna-Star™
1500 psi (10.5 MPa, 105 bar) Maximum Working Pres- sure 3 gpm (11 liters/min) Maximum Flow Rate
Used with Power-Star™
Hydraulic fluid controls are designed to control hydraulic fluids only in a hydraulic power system. Any other fluids can cause unsafe operating conditions and results in component rupture, fire, or explosion which could result in serious injury, including fluid injection.
1500 psi (10.5 MPa, 150 bar) Maximum Working Pres- sure 12 gpm (45 liters/min) Maximum Flow Rate
Model 236864 · Model 236865

The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama- tion point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When these symbols appear in the body of this manual or on warning labels, refer back to these Warnings. Product-specific hazard symbols and warnings not covered in this section may appear throughout the body of this manual where applicable.


Grounding
The equipment must be grounded to reduce the risk of static sparking and electric shock. Electric or static sparking can cause fumes to ignite or explode. Improper grounding can cause electric shock. Grounding provides an escape wire for the electric current.
Pump: use ground wire and clamp (supplied). Loosen grounding lug locknut (W) and washer (V). Insert one end of a 12 ga (1.5 mm2) minimum ground wire (Y) into the slot in lug (Z) and tighten the locknut securely. Con- nect the other end of the wire to a true earth ground. Order Part No. 237569 Ground Wire and Clamp.
Hydraulic Hoses and Fluid Outlet Hoses: use only electrically conductive hoses.
Hydraulic Power Supply and Air Compressor: follow manufacturer’s recommendations.
Any pails used when flushing: use only metal grounded pails when flushing. Make firm metal-to-metal contact between a metal part of the dispense valve and the pail. Use the lowest possible pressure.
Installation



Model 236865 Model 236864
Key: A Hydraulic Control, 236864 B Hydraulic Control, 236865 C Hydraulic Return Line D Hydraulic Outlet, 3/4 npsm (A), 1 1/4 npsm(B) E Return Line Shutoff Valve F Hydraulic Inlet, 3/8 npsm (A), 3/4 npsm (B) G Supply Line Shutoff Valve H Pressure Gauge J Pressure Reducing Valve K Flow Control Valve L Hydraulic Supply Line (use only Graco hydraulic power supply)
Pressure Regulation: The hydraulic fluid control pres- sure reducing valve (J) reduces the hydraulic oil pres- sure to the operating pressure required for application.
Flow Regulation: The hydraulic fluid control valve (K) limits the maximum amount of oil flow to the motor to keep the hydraulic motor within the recommended cycle rate limit. This prevents pump runaway. The limit on the Dyna-Star™ is 60 cpm. The limit on the Power-Star™ is 66 cpm.
Pump Isolation: The hydraulic fluid control (A and B) has ball valves on the supply and return sides of the mani- fold. The ball valves isolate the hydraulic fluid control and pump for servicing without stopping the hydraulic power source.
Hydraulic Fluid Control: The hydraulic fluid control pro- vides pressure regulation, flow regulation, and pump isolation. See the Typical Installation as a guide. For assistance in designing a system to suit your needs, contact your Graco Representative.
Installation

Hydraulic Components
The hydraulic supply system must be kept clean at all times to reduce the risk of damaging the reciprocator hydraulic power supply.
Maximum Working Pressure of Accessories
To reduce the risk of over pressurizing the hydraulic reciprocator, which could cause a rupture and serious injury, including fluid injection, the hydraulic power must have a means to limit the incoming fluid flow to the reciprocator to a maximum of 3 gpm (11 liter/min) at 1500 psi (10.5 MPa, 105 bar) for the Dyna-Star™ and 10 gpm (37 liter/min) at 1500 psi (10.5 MPa, 105 bar) for the Power-Star™.
Use Graco approved Hydraulic Oil or a premium ISO grade 46 petroleum-based hydraulic oil containing rust and oxidation inhibitors and anti-wear agents.
Installation

Pressure Relief Procedure
Hydraulic Fluid Level Check
Follow the Pressure Relief Procedure whenever you see this symbol.
Check the hydraulic fluid level in the hydraulic power supply before each use, and add fluid as necessary to fill the lines.
This equipment stays pressurized until pressure is manually relieved. To help prevent serious injury from pressurized fluid, such as skin injection, splashing fluid and moving parts, follow the Pressure Relief Procedure when you stop spraying and before cleaning, checking, or servicing the equipment.
If you suspect that the dispensing valve nozzle or hose is completely clogged, or that pressure has not been fully relieved after following the steps above, VERY SLOWLY loosen the hose end coupling and relieve pres- sure gradually then loosen completely, now clear the obstruction.
Close the red-marked supply line shutoff valve marked STOP.
When starting up the hydraulic system, open the return line shutoff valve (E) first.
Operation

Always shut off the supply line shutoff valve (E) first, and then the return line shutoff valve (G). This is to prevent over pressurizing the reciprocator or its seals. When starting the hydraulic system, open the return line shut- off valve (G) first. See page 5.
Flow Control Repair
There are two basic repairs to the hydraulic fluid control; pressure control repair and flow control repair.
Repair

Troubleshooting

113 Includes items 113a & 113b
Ref. Part Description Qty.
Ref. Part Description Qty. 102 108537 VALVE, ball 1 103 112714 HOSE, coupled, 3 ft 2 104 112567 GAUGE, pressure, fluid 1 105 112578 VALVE, ball 1 106 112581 SWIVEL, union, 90° 1 107 112705 SWIVEL, union, 90° 1 108 112707 ADAPTER, male 1 109 112708 ADAPTER, male 1 110 112715 HOUSE, couple, 3 ft 2
111 155494 UNION, swivel, 90° 1 112 160327 UNION, swivel, 90° 1 113 189837 MANIFOLD, 3 gpm, includes replaceable items 113a and 113b
113a 119902 VALVE, pressure reducing 1 113b 112712 VALVE, flow regulating, 3 gpm 1
Parts · 113b · 113a

108 Includes items 113a & 113b
Ref. Part Description Qty. 102 108537 VALVE, ball 1 103 112567 GAUGE, pressure, fluid 1 104 112579 VALVE, ball 1 105 112580 SWIVEL, union, 90° 1 106 112705 SWIVEL, union, 90° 1 107 112706 SWIVEL, union, 90° 1 108 112708 ADAPTER, male 1 109 112709 ADAPTER, male 1 110 112715 HOSE, coupled, 3 ft 2
Ref. Part Description Qty.
111 112716 HOSE, coupled, 3 ft 2 112 160327 UNION, swivel, 90° 1 113 189838 MANIFOLD, 12 gpm, includes items 113a and 113b
113a 119903 VALVE, pressure reducing 1 113b 112713 VALVE, flow regulating, 12 gpm
Parts · 113b · 113a

3 x 0.406 in. Use 3/8 in. (9 mm) screws
3 x 0.406 in. Use 3/8 in. (9 mm) screws
1.875 in. (47.63 mm)
3.75 in. (95.25 mm)
2.125 in. (53.97 mm) 4.25 in. (107.95 mm)
4.25 in. (107.95 mm)
5.25 in. (133.35 mm)
Model 236864 Model 236865
Technical Data


Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.
GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite de ou en rapport, directement ou indirectement, avec les procédures concernées.
For the latest information about Graco products, visit www.graco.com
TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor. Phone: 612-623-6928 or Toll Free: 1-800-533-9655, Fax: 612-378-3590.
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
For patent information, see www.graco.com/patents
Original instructions. This manual contains English. MM 308395
Copyright 1994, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.
www.graco.com Revised November 2012
Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| No pressure on gauge, or low pres- sure on gauge | Hydraulic power supply malfunction or mis-adjustment | Adjust the hydraulic power supply. If the problem remains, refer to the hydraulic power supply instruction manual. | p.9 |
| No pressure on gauge, or low pres- sure on gauge | Pressure reducing valve is backed out | Adjust the pressure reducing valve. | p.9 |
| Can’t adjust pressure with the pres- sure reducing valve | Clogged valve | Clean the pressure reducing valve. | p.9 |
| Can’t adjust pressure with the pres- sure reducing valve | Insufficient hydraulic power supply pressure | Adjust the hydraulic power supply pressure. If problem remains refer to the hydraulic power supply instruction manual. | p.9 |
| Gauge will not re-zero with the hydraulic supply and return line shutoff valves closed | Leak in the supply line shutoff valve (G) | Open the return line shutoff valve (E) to remove pressure. | p.9 |
| Gauge will not re-zero with the hydraulic supply and return line shutoff valves closed | Damaged gauge | Replace gauge. | p.9 |
| Pump runs away | Contaminated flow control valve | Remove and clean the flow control valve. | p.9 |