Instructionsp.1Partsp.1CARBON STEEL Check–Mate ™ 800 Pumpsp.1308351Kp.1With Priming Piston and Severe–Duty Rod and Cylinderp.14990Bp.1Symbolsp.3Warning Symbolp.3Caution Symbolp.3CAUTIONp.3EQUIPMENT MISUSE HAZARDp.3SKIN INJECTION HAZARDp.4MOVING PARTS HAZARDp.4FIRE AND EXPLOSION HAZARDp.5TOXIC FLUID HAZARDp.5Installationp.6Groundingp.6X Yp.6Y Zp.6TI1052p.6All Systemsp.7System Accessoriesp.7Installation (Air–Powered Pumps)p.8KEYp.8Installation (Hydraulic–Powered Pumps)p.10H Mp.10G P Qp.10Y Cp.10E Dp.10Operationp.12Pressure Relief Procedurep.12Packing Nut/Wet-Cupp.12Flush the Pump Before First Usep.13Starting and Adjusting the Pumpp.13Notesp.15Maintenancep.16Shutdown and Care of the Pumpp.16Flushingp.16Troubleshootingp.17PROBLEM CAUSE SOLUTIONp.17Servicep.18Required Toolsp.18Disconnecting the Displacement Pumpp.18Reconnecting the Displacement Pumpp.19Displacement Pump Servicep.20Disassemblyp.20DETAIL OF INTAKE CHECK VALVEp.20THROAT PACKING DETAILp.21DETAIL OF PISTON CHECK VALVEp.22Reassemblyp.2316 15 Vp.24For Pumps 198466, 237265 and 236471 onlyp.26For Pumps 246938, 246940, 246941 and 246942 onlyp.27Servicing the Throat Packingsp.27Part No. 236471 Pump, Series B, 65:1 Ratio, with King Air Motorp.28Part No. 246942 Pump, Series A, 65:1 Ratio, with King Air Motorp.28Part No. 237261 Pump, Series A, 31:1 Ratio, with Bulldog Air Motorp.28Part No. 246940 Pump, Series A, 31:1 Ratio, with Bulldog Air Motorp.28Part No. 237264 Pump, Series A, 19:1 Ratio, with Senator Air Motorp.28Part No. 246941 Pump, Series A, 19:1 Ratio, with Senator Air Motorp.28Part No. 241901 Pump, Series A, 31:1 Ratio, with Bulldog Air Motorp.2804994Bp.28Part No. 198466 Pump, Series A, with Viscount II Hydraulic Motorp.30Part No. 246938 Pump, Series A, with Viscount II Hydraulic Motorp.3004991Bp.31Displacement Pump Partsp.32Part No. 246939, Series A,p.32Part No. 236611, 198469 and 237945; Series Ap.34Part No. 236611 and 198469, Series A, Standard UHMWPE/PTFE Packed Displacement Pumpp.36THROAT PACKINGS: LIPS FACE DOWNp.36INTAKE PACKINGS: LIPS FACE UPp.36LUBRICATE PACKINGSp.36Part No. 237945, Series A, Optional PTFE Packed Displacement Pumpp.36LUBRICATE PACKINGS *5p.36Technical Datap.38(Model 236471 and 246942 King Pumps)p.38Performance Chartsp.39Test Fluid: No. 10 Weight Oilp.39AIR CONSUMPTIONp.39FLUID PRESSUREp.39
Page 1 of the Graco 308351K user manual — 4990B
Page 1 · click to enlarge
Page 1

Instructions

Parts

CARBON STEEL Check–Mate ™ 800 Pumps

308351K

Graco 308351K — Parts diagram (page 1)
Fig. 1 · Parts

With Priming Piston and Severe–Duty Rod and Cylinder

Refer to page 2 for Table of Contents.

US Patent Nos. 5,147,188 and 5,154,532. Other patents pending.

Models 237265, 246940 and 246941

4990B

Show 5 more labels / short text on this page
Models 236471 · and 246942 · Models 198466 · and 246938 · ti1447a
Page 2 of the Graco 308351K user manual — Instructions
Page 2 · click to enlarge
Page 2
Page 2 of the Graco 308351K user manual — Instructions
Page 3 of the Graco 308351K user manual — INSTRUCTIONS
Page 3 · click to enlarge
Page 3

Symbols

Warning Symbol

Caution Symbol

CAUTION

his symbol alerts you to the possibility of serious injury or death if you do not follow the instructions.

This symbol alerts you to the possibility of damage to or destruction of equipment if you do not follow the instructions.

EQUIPMENT MISUSE HAZARD

Equipment misuse can cause the equipment to rupture or malfunction and result in serious injury.

INSTRUCTIONS

This equipment is for professional use only.

Read all instruction manuals, tags, and labels before operating the equipment.

Use the equipment only for its intended purpose. If you are not sure, call your Graco distributor.

Do not alter or modify this equipment.

Check equipment daily. Repair or replace worn or damaged parts immediately.

Do not exceed the maximum working pressure stated on the equipment or in the Technical Data for your equipment. Do not exceed the maximum working pressure of the lowest rated component in your system.

Use fluids and solvents which are compatible with the equipment wetted parts. Refer to the Tech- nical Data section of all equipment manuals. Read the fluid and solvent manufacturer’s warnings.

Do not use hoses to pull equipment.

Route hoses away from traffic areas, sharp edges, moving parts, and hot surfaces. Do not expose Graco hoses to temperatures above 82C (180F) or below –40C (–40F).

Wear hearing protection when operating this equipment.

Do not lift pressurized equipment.

Comply with all applicable local, state, and national fire, electrical, and safety regulations.

Page 4 of the Graco 308351K user manual — MOVING PARTS HAZARD
Page 4 · click to enlarge
Page 4

SKIN INJECTION HAZARD

Spray from the spray gun/dispense valve, leaks or ruptured components can inject fluid into your body and cause extremely serious injury, including the need for amputation. Fluid splashed in the eyes or on the skin can also cause serious injury.

Fluid injected into the skin might look like just a cut, but it is a serious injury. Get immediate surgi- cal treatment.

Do not point the gun/valve at anyone or at any part of the body.

Do not put your hand or fingers over the spray tip/nozzle.

Do not stop or deflect leaks with your hand, body, glove or rag.

Do not “blow back” fluid; this is not an air spray system.

Always have the tip guard and the trigger guard on the gun when spraying.

Check the gun diffuser operation weekly. Refer to the gun manual.

Be sure the gun/valve trigger safety operates before spraying.

Lock the gun/valve trigger safety when you stop spraying.

Follow the Pressure Relief Procedure on page 12 if the spray tip/nozzle clogs and before clean- ing, checking or servicing the equipment.

Tighten all fluid connections before operating the equipment.

Check the hoses, tubes, and couplings daily. Replace worn or damaged parts immediately. Do not repair high pressure couplings; you must replace the entire hose.

Fluid hoses must have spring guards on both ends, to help protect them from rupture caused by kinks or bends near the couplings.

MOVING PARTS HAZARD

Moving parts, such as the priming piston, can pinch or amputate your fingers.

Keep clear of all moving parts when starting or operating the pump.

Before servicing the equipment, follow the Pressure Relief Procedure on page 12 to prevent the equipment from starting unexpectedly.

Page 5 of the Graco 308351K user manual — TOXIC FLUID HAZARD
Page 5 · click to enlarge
Page 5

FIRE AND EXPLOSION HAZARD

Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and result in a fire or explosion and serious injury.

Ground the equipment and the object being sprayed. Refer to Grounding on page 6.

If there is any static sparking or you feel an electric shock while using this equipment, stop spray- ing/dispensing immediately. Do not use the equipment until you identify and correct the problem.

Provide fresh air ventilation to avoid the buildup of flammable fumes from solvents or the fluid being sprayed/dispensed.

Keep the spray/dispense area free of debris, including solvent, rags, and gasoline.

Electrically disconnect all equipment in the spray/dispense area.

Extinguish all open flames or pilot lights in the spray/dispense area.

Do not smoke in the spray/dispense area.

Do not turn on or off any light switch in the spray/dispense area while operating or if fumes are present.

Do not operate a gasoline engine in the spray/dispense area.

TOXIC FLUID HAZARD

Hazardous fluid or toxic fumes can cause serious injury or death if splashed in the eyes or on the skin, inhaled, or swallowed.

Know the specific hazards of the fluid you are using.

Store hazardous fluid in an approved container. Dispose of hazardous fluid according to all local, state and national guidelines.

Always wear protective eyewear, gloves, clothing and respirator as recommended by the fluid and solvent manufacturer.

Page 6 of the Graco 308351K user manual — TI1052
Page 6 · click to enlarge
Page 6

Installation

Grounding

W

X Y

FIRE AND EXPLOSION HAZARD Before operating the pump, ground the system as explained below. Also read the section FIRE AND EXPLOSION HAZARD on page 5.

Z

1. King Pumps: use a ground wire and clamp. See Fig. 1. Remove the ground screw (Z) and insert through eye of ring terminal at the end of ground wire (Y). Fasten ground screw back onto pump and tighten securely. Connect the other end of the wire to a true earth ground. Order Part No. 222011 Ground Wire and Clamp.
2. Air and fluid hoses: use only electrically conductive hoses.
3. Air compressor: follow manufacturer’s recommendations.

All other Pumps: use a ground wire and clamp. See Fig. 2. Loosen the grounding lug locknut (W) and washer (X). Insert one end of a 1.5 mm2 (12 ga) minimum ground wire (Y) into the slot in lug (Z) and tighten the locknut securely. Connect the other end of the wire to a true earth ground. Order Part No. 222011 Ground Wire and Clamp.

4. Spray gun/dispense valve: ground through connection to a properly grounded fluid hose and pump.
5. Fluid supply container: follow your local code.
6. Object being sprayed: follow your local code.
7. All solvent pails used when flushing: follow your local code. Use only metal pails, which are conductive, placed on a grounded surface. Do not place the pail on a nonconductive surface, such as paper or cardboard, which interrupts the grounding continuity.

Y Z

8. To maintain grounding continuity when flushing or relieving pressure , always hold a metal part of the gun/valve firmly to the side of a grounded metal pail, then trigger the gun/valve.

TI1052

·

Page 7 of the Graco 308351K user manual — All Systems
Page 7 · click to enlarge
Page 7

Installation

All Systems

System Accessories

Air and Fluid Hoses

Be sure all air hoses and fluid hoses are properly sized and pressure-rated for your system. Use only electri- cally conductive hoses. Fluid hoses must have spring guards on both ends.

The Typical Installations shown in Figs. 3 and 4 are only guides for selecting and installing system compo- nents and accessories. Contact your Graco distributor for assistance in designing a system to suit your particular needs.

Mounting Accessories (Except 198466, 198475 and 246938)

Mount the pump (A) to suit the type of installation planned. Fig. 3 on page 8 illustrates a ram-mounted pump in a multi-gun header system. Pump dimensions and the mounting hole layout are shown on page 49.

Accessories are available from Graco. If you supply your own accessories, be sure they are adequately sized and pressure–rated to meet the system’s re- quirements.

If you are mounting the pump on a ram, refer to the separate ram manual for installation and operation instructions. Mounting Kit 222776 is available to mount the pump on a 55 gallon (200 liter) ram.

Page 8 of the Graco 308351K user manual — KEY
Page 8 · click to enlarge
Page 8

Installation (Air–Powered Pumps)

KEY

A Pump B 200 Liter (55 Gallon) Air-Powered Ram C Main Air Bleed Valve (required, for pump and ram) D Air Line Lubricator (position only) E Pump Air Bleed Valve (required, for pump) F Pump Air Regulator G Air Manifold H Electrically Conductive Air Supply Hose J Air Line Filter K Air Shutoff Valve (for accessories) L Fluid Regulator

M Fluid Drain Valve (required) N Electrically Conductive Fluid Supply Hose P Fluid Shutoff Valve R Gun/Valve Swivel S Airless Spray Gun or Dispensing Valve T Ram Air Regulator U Ram Director Valve V Pump Runaway Valve (position only) W Air LIne Drain Valve Y Ground Wire (required, see page 6 for installation instructions)

FLUID HEADER PIPE (3 in. Diameter)

Graco 308351K — KEY diagram (page 8)
Fig. 2

Fig. 3

Page 9 of the Graco 308351K user manual — Installation (Air–Powered Pumps)
Page 9 · click to enlarge
Page 9

Installation (Air–Powered Pumps)

A pump runaway valve (V) senses when the pump is running too fast and automatically shuts off the air to the motor. A pump which runs too fast can be seriously damaged. Locate in the position shown.

A main air bleed valve (C), pump air bleed valve (E), and fluid drain valve (M) are required. These accessories help reduce the risk of serious injury, including fluid injection and splashing of fluid in the eyes or on the skin, and injury from moving parts if you are adjusting or repairing the pump.

An air manifold (G) has a swivel air inlet. It mounts to a ram, and has ports for connecting lines to air accessories, such as the ram air regulator (T) and ram director valve (U).

The main air bleed valve (C) shuts off the air to the pump and ram. The pump air bleed valve (E) relieves air trapped between this valve and the pump after the air is shut off. Trapped air can cause the pump to cycle unexpectedly. Locate the valve close to the pump. Order Part No. 107141.

An air line filter (J) removes harmful dirt and moisture from the compressed air supply. Also, install a drain valve (W) at the bottom of each air line drop, to drain off moisture.

The fluid drain valve assists in relieving fluid pres- sure in the displacement pump, hose, and gun. Triggering the gun to relieve pressure may not be sufficient. Order Part No. 210658.

An air shutoff valve (K) isolates the air line acces- sories for servicing. Locate upstream from all other air line accessories.

Install the following accessories in the positions shown in Figs. 3 and 4, using adapters as necessary:

Install the following accessories in the order shown in Fig. 3, using adapters as necessary:

Install a fluid shutoff valve (P) at each gun/valve drop, to isolate the gun/valve and fluid accessories for servicing.

An air line lubricator (D) provides automatic air motor lubrication. Locate in the position shown.

A main air bleed valve (C) is required in your system to shut off the air supply to the pump and ram (see the WARNING above). When closed, the valve will bleed off all air in the ram and pump, and the ram will slowly lower. Be sure the valve is easily accessible from the pump, and is located upstream from the air manifold (G).

Install a fluid drain valve (M) near the pump fluid outlet, and at each gun/valve station. The drain valves are required in your system to relieve fluid pressure in the displacement pump, hose and gun/valve (see the WARNING at left). Drain valves at the gun/valve stations may be mounted in the base of a fluid regulator (L), using an adapter.

A pump air bleed valve (E) is required in your system to relieve air trapped between it and the air motor when the valve is closed (see the WARNING at left). Be sure the bleed valve is easily accessible from the pump, and is located downstream from the air regulator.

A fluid regulator (L) controls fluid pressure to the gun/valve, and dampens pressure surges.

A gun or dispense valve (S) dispenses the fluid. The gun shown in Fig. 3 is a high pressure dispens- ing gun for highly viscous fluids.

An air regulator (F) controls pump speed and outlet pressure by adjusting the air pressure to the pump. Locate the regulator close to the pump, but upstream from the pump air bleed valve.

A gun/valve swivel (R) allows freer gun/valve movement.

Fluid Line Accessories · Air Line Accessories ·

Page 10 of the Graco 308351K user manual — H M
Page 10 · click to enlarge
Page 10

Installation (Hydraulic–Powered Pumps)

KEY

A Accessory Pump Stand (P/N 218742) B Surge Tank (P/N 218509 or 238983) C 50 mm (2 in.) Diameter Pipe D Full Flow, Non-Restrictive Fluid Shutoff Valve E Fluid Supply Line F Mix Tank G Hydraulic Supply Line Shutoff Valve

H Hydraulic Pressure Gauge J Flow Control Valve K Pressure Reducing Valve L Drain Line M Hydraulic Return Line Shutoff Valve N Accumulator P Hydraulic Supply Line Q Hydraulic Return Line Y Ground Wire (required, see page 6)

H M

K

N

G P Q

F

J

Y C

F

Y

B

E D

A

D

E D

Page 11 of the Graco 308351K user manual — CAUTION
Page 11 · click to enlarge
Page 11

Installation (Hydraulic–Powered Pumps)

CAUTION

The Hydraulic Power Supply must be kept clean at all times to avoid damage to the motor and hydraulic power supply.

1. Blow out hydraulic lines with air and flush thoroughly before connection to the motor.

On the hydraulic oil supply line (P), install a shutoff valve (G) to isolate the system for servicing; a fluid pressure gauge (H) to monitor hydraulic oil pressure to the motor and avoid overpressurizing the motor or displacement pump; a pressure- and temperature- compensated flow control valve (J) to prevent the motor from running too fast; a pressure reducing valve (K) with a drain line (L) running directly into the hydrau- lic return line (Q); and an accumulator (N) to reduce the hammering effect caused by the motor reversing direction.

2. Plug hydraulic inlets, outlets, and line ends when disconnecting them for any reason.

Always plug the hydraulic inlets, outlets and lines when disconnecting them for any reason to avoid introducing dirt and other contaminants into the system.

Be sure that your hydraulic power supply is equipped with a suction filter to the hydraulic pump and a system return line filter of 10 micron size. Carefully follow the manufacturer’s recommendations on reservoir and filter cleaning and periodic changes of hydraulic fluid.

On the hydraulic return line (Q), install a shutoff valve (M) for isolating the motor for servicing.

Page 12 of the Graco 308351K user manual — Packing Nut/Wet-Cup
Page 12 · click to enlarge
Page 12

Operation

Pressure Relief Procedure

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure at left.

SKIN INJECTION HAZARD The system pressure must be manually relieved to prevent the system from starting or spraying accidentally. Fluid under high pressure can be injected through the skin and cause serious injury. To reduce the risk of an injury from injection, splashing fluid, or moving parts, follow the Pressure Relief Procedure whenever you:

The packing nut is torqued at the factory and is ready for operation. If it becomes loose and there is leaking from the throat packings, relieve pressure, then torque the nut to 128–156 N.m (95–115 ft-lb) using the supplied wrench (109). Do this whenever necessary. Do not overtighten the packing nut.

are instructed to relieve the pressure, stop spraying/dispensing, check or service any of the system equipment, or install or clean the spray tip/nozzle.

1. Lock the gun/valve trigger safety.
2. Shut off the power to the pump.
3. In an air-powered system, close the air regulator and close the bleed-type master air valve.
4. In a hydraulic-powered system, close the hydraulic supply line shutoff valve first, then the return line shutoff valve.
5. Unlock the gun/valve trigger safety.
6. Hold a metal part of the gun/valve firmly to the side of a grounded metal pail, and trigger the gun/valve to relieve pressure.
7. Lock the gun/valve trigger safety.
8. In an air–powered system, open the drain valve (required in your system), having a container ready to catch the drainage. Leave the drain valve open until you are ready to spray/dispense again.

If you suspect that the spray tip/nozzle or hose is completely clogged, or that pressure has not been fully relieved after following the steps above, very slowly loosen the tip guard retaining nut or hose end coupling and relieve pressure gradually, then loosen completely. Now clear the tip/nozzle or hose.

Bleed hole must face down.

21 Torque to 128–156 N.m (95–115 ft-lb).

Packing Nut/Wet-Cup

Before starting, fill the packing nut (2) 1/3 full with Graco Throat Seal Liquid (TSL) or compatible solvent. See Fig. 5.

04995 Fig. 5

Page 13 of the Graco 308351K user manual — CAUTION
Page 13 · click to enlarge
Page 13

Operation

Flush the Pump Before First Use

The pump is tested with lightweight oil, which is left in to protect the pump parts. If the fluid you are using may be contaminated by the oil, flush it out with a compatible solvent. See Flushing on page 16.

COMPONENT RUPTURE HAZARD To reduce the risk of overpressurizing your system, which could cause compo- nent rupture and serious injury, never exceed the Maximum Input Pressure to the pump (see the Technical Data on pages 38–46).

Starting and Adjusting the Pump

1. Supply fluid to the pump, per the requirements of your system.
2. See Fig. 3. Close the air regulator (F).

MOVING PARTS HAZARD Keep hands and fingers away from the priming piston (21) during operation and whenever the pump is charged with air. The priming piston extends beyond the intake housing (19) to pull material into the pump and can amputate a hand or finger caught between it and the intake housing. Follow the Pressure Relief Procedure on page 12, before checking, clearing, or cleaning the priming piston.

3. Open all air bleed valves (C, E).
4. Hold a metal part of the gun/valve (S) firmly to the side of a grounded metal pail and hold the trigger open.
5. Slowly open the air regulator until the pump starts.
6. Cycle the pump slowly until all air is pushed out and the pump and hoses are fully primed.
7. Release the gun/valve trigger and lock the trigger safety. The pump should stall against pressure.
8. If the pump fails to prime properly, open the bleeder valve plug (20) slightly. Use the bleed hole, on the underside of the valve body (29), as a priming valve until the fluid appears at the hole. See Fig. 5. Close the plug.

SKIN INJECTION HAZARD To reduce the risk of fluid injection, do not use your hand or fingers to cover the bleed hole on the underside of the bleeder valve body (29) when priming the pump. Use a crescent wrench to open and close the bleeder plug (20). Keep your hands away from the bleed hole.

9. With the pump and lines primed, and with adequate air pressure and volume supplied, the pump will start and stop as you open and close the gun/valve. In a circulating system, the pump will speed up or slow down on demand, until the air supply is shut off.

CAUTION

Do not allow the pump to run dry. It will quickly accelerate to a high speed, causing damage. If your pump is running too fast, stop it immediately and check the fluid supply. If the container is empty and air has been pumped into the lines, refill the con- tainer and prime the pump and the lines, or flush and leave it filled with a compatible solvent. Eliminate all air from the fluid system.

10. Use the air regulator (F) to control the pump speed and the fluid pressure. Always use the lowest air pressure necessary to get the desired results. Higher pressures cause premature tip/nozzle and pump wear.

Air–Powered Systems ·

Page 14 of the Graco 308351K user manual — Operation
Page 14 · click to enlarge
Page 14

Operation

c. Adjust the pressure–reducing valve until you

get the desired fluid pressure. Run the pump until all air is purged from the fluid lines.

Refer to the warnings on page 13.

1. Supply fluid to the pump, per the requirements of your system.

d. Count the cycle rate of the pump.

2. Open the shutoff valves between the pump and supply tanks.

e. Close the flow control valve until the cycle rate

and fluid pressure start to drop.

3. Open the dispensing valve(s) or spray gun(s).

f. Open the flow control valve slightly until the

cycle rate and fluid pressure return to the desired level. This method of setting the hy- draulic controls ensures proper pump opera- tion and will prevent pump runaway and dam- age if the fluid supply runs out.

4. To adjust the system, perform the following procedure:

a. Turn on the hydraulic power supply.

b. Open the flow control valve all the way.

g. Close the gun or valve.

Hydraulic–Powered Systems ·

Page 15 of the Graco 308351K user manual — Notes
Page 15 · click to enlarge
Page 15

Notes

Page 16 of the Graco 308351K user manual — Flushing
Page 16 · click to enlarge
Page 16

Maintenance

Shutdown and Care of the Pump

CAUTION

Never leave water or water-base fluid in the pump overnight. If you are pumping water-base fluid, flush with water first, then with a rust inhibitor such as mineral spirits. Relieve the pressure, but leave the rust inhibitor in the pump to protect the parts from corrosion.

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 12.

For overnight shutdown, stop the pump at the bottom of the stroke to prevent fluid from drying on the ex- posed displacement rod and damaging the throat packings. Relieve the pressure.

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 12.

Always flush the pump before the fluid dries on the displacement rod. Refer to Flushing below.

Flushing

1. Relieve the pressure.
2. Remove the spray tip/nozzle from the gun/valve.

FIRE AND EXPLOSION HAZARD Before flushing, read the section FIRE AND EXPLOSION HAZARD on page 5. Be sure the entire system and flush- ing pails are properly grounded. Refer to Grounding on page 6.

3. Hold a metal part of the gun/valve firmly to the side of a grounded metal pail.
4. Start the pump. Always use the lowest possible fluid pressure when flushing.

Flush with a fluid that is compatible with the fluid you are pumping and with the wetted parts in your system. Check with your fluid manufacturer or supplier for recommended flushing fluids and flushing frequency. Always flush the pump before fluid dries on the dis- placement rod.

5. Trigger the gun/valve.
6. Flush the system until clear solvent flows from the gun/valve.
7. Relieve the pressure.

Page 17 of the Graco 308351K user manual — PROBLEM CAUSE SOLUTION
Page 17 · click to enlarge
Page 17

Troubleshooting

1. Relieve the pressure.
2. Check all possible problems and causes before disassembling the pump.

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 12.

PROBLEM CAUSE SOLUTION

Pump fails to operate. Restricted air or hydraulic line or inade- quate air supply; closed or clogged valves.

Clear any obstructions; check that all valves are open; increase pressure.

Obstructed fluid hose or gun/valve; fluid hose ID is too small.

Open, clear*; use a hose with a larger ID.

Fluid dried on the displacement rod. Clean; always stop the pump at the bottom of its stroke; keep the wet-cup 1/3 filled with a compat- ible solvent.

Dirty, worn, or damaged motor parts. Clean or repair; see the separate motor manual.

Pump operates, but output low on both strokes.

Restricted air or hydraulic line or inade- quate air supply; closed or clogged valves.

Clear any obstructions; check that all valves are open; increase pressure.

Obstructed fluid hose or gun/valve; fluid hose ID is too small.

Open, clear*; use a hose with a larger ID.

Bleeder valve is open. Close the valve.

Air is leaking into the supply container. Check the ram plate seal.

Fluid is too heavy for pump priming. Use the bleeder valve (see page 13); use a ram.

Held open or worn intake valve or seals. Clear the valve; replace the seals.

Worn packings in the displacement pump.

Replace the packings.

Pump operates, but output low on down- stroke.

Fluid too heavy for pump priming. Use the bleeder valve (see page 13); use a ram.

Held open or worn intake valve or seals. Clear the valve; replace the seals.

Pump operates, but output low on upstroke.

Held open or worn piston valve or seals. Clear the valve; replace the seals.

THE TROUBLESHOOTING CHART IS CONTINUED ON PAGE 18.

* To determine if the fluid hose or gun is obstructed, follow the Pressure Relief Procedure on page 12. Dis- connect the fluid hose and place a container at the pump fluid outlet to catch any fluid. Turn on the air or hydraulic power just enough to start the pump. If the pump starts, the obstruction is in the fluid hose or gun.

Page 18 of the Graco 308351K user manual — Disconnecting the Displacement Pump
Page 18 · click to enlarge
Page 18

Troubleshooting

PROBLEM CAUSE SOLUTION

Erratic or accelerated pump speed.

Exhausted fluid supply. Refill and prime.

Fluid is too heavy for pump priming. Use the bleeder valve (see page 13 or 14); use a ram.

Held open or worn piston valve or seals. Clear the valve; replace the seals.

Held open or worn priming piston. Clear; service.

Worn packings in the displacement pump.

Replace the packings.

Service

Required Tools

4. Disconnect the displacement pump (106) from the motor (101) as follows. See Fig. 6. Be sure to note the relative position of the pump’s fluid outlet (X) to the motor inlet (Y). If the motor does not require servicing, leave it attached to its mounting.

Bench vise, with soft jaws

CAUTION

13 mm (1/2 in.) dia. brass rod

Be sure to use at least two people when lifting, moving, or disconnecting the pump. This pump is too heavy for one person. If you are disconnecting the displacement pump from a motor which is still mounted (for example, on a ram), be sure to support the displacement pump while it is being discon- nected, to prevent it from falling and causing injury or property damage. Do this by securely bracing the pump, or by having at least two people hold it while another disconnects it.

Set of socket wrenches

Set of adjustable wrenches

Packing nut wrench (109, supplied)

Disconnecting the Displacement Pump

1. Flush the pump, if possible. Stop the pump at the bottom of its stroke.
5. Using an adjustable wrench (or a hammer and rod), unscrew the coupling nut (104) from the motor shaft (Z). Do not lose or drop the coupling collars (105). See Fig. 6.
6. Hold the tie rod flats with a wrench to keep the rods from turning. Unscrew the nuts (103) from the tie rods (102). Carefully remove the displacement pump (106) from the motor (101).

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 12.

2. Relieve the pressure.
7. Refer to page 20 for displacement pump service. To service the motor, refer to the separate motor manual, supplied.
3. Disconnect all hoses from the pump and motor.
Show 8 more labels / short text on this page
Torque wrench · Rubber mallet · Hammer · O-ring pick · Pipe wrench · Thread lubricant · Thread sealant ·
Page 19 of the Graco 308351K user manual — Z
Page 19 · click to enlarge
Page 19

Service

Reconnecting the Displacement Pump

1. Make sure the coupling nut (104) and the coupling collars (105) are in place on the displacement rod (1). See Fig. 6.

Y

2. Use at least two people to hold the displacement pump while another reconnects it to the motor (see the CAUTION on page 18). Orient the pump’s fluid outlet (X) to the air or hydraulic inlet (Y) as was noted in step 4 under Disconnecting the Displacement Pump. Position the displacement pump (106) on the tie rods (102).
3. Screw the nuts (103) onto the tie rods (102) and torque to 68–81 N.m (50–60 ft-lb).

Z

4. Screw the coupling nut onto the motor shaft loosely. Hold the motor shaft (Z) flats with a wrench to keep it from turning. Use an adjustable wrench to tighten the coupling nut. Torque to 196–210 N.m (145–155 ft-lb).
5. Torque the packing nut (2) to 128–156 N.m (95–115 ft-lb).
6. Reconnect all hoses. Reconnect the ground wire if it was disconnected. Fill the wet-cup (2) 1/3 full of Graco Throat Seal Liquid or compatible solvent.
7. Turn on the power supply. Run the pump slowly to ensure proper operation.

Torque to 68–81 N.m (50–60 ft-lb).

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 12.

Torque to 196–210 N.m (145–155 ft-lb).

Torque to 128–156 N.m (95–115 ft-lb).

Square hole is for use with torque wrench.

8. Before returning the pump to production, relieve the pressure and retorque the packing nut (2) to 128–156 N.m (95–115 ft-lb).

04994 Fig. 6

Show 5 more labels / short text on this page
102 105 · · 106 103 · ·
Page 20 of the Graco 308351K user manual — N
Page 20 · click to enlarge
Page 20

Displacement Pump Service

Disassembly

When disassembling the pump, lay out all the removed parts in sequence, to ease reassembly. Clean all parts with a compatible solvent and inspect them for wear or damage. Refer to Fig. 9 for a cutaway view of the pump.

5. Unscrew the intake valve housing (17) from the cylinder (10). Pull the housing off the pump. The intake check valve assembly (V, see Fig. 7) should slide down the priming piston rod (18) as you remove the housing; if it does not slide easily, firmly tap on the top of the housing (17) with a rubber mallet to loosen.
1. Remove the displacement pump from the motor as explained on page 18. Place the pump in a vise, with the outlet housing (9) positioned as shown in Fig. 8.

DETAIL OF INTAKE CHECK VALVE

Graco 308351K — DETAIL OF INTAKE CHECK VALVE diagram (page 20)
Fig. 3
2. Hold the flats of the priming piston rod (18) with an adjustable wrench, and use a second wrench to unscrew the priming piston seat (22) from the rod. Slide the priming piston (21) off the rod. Inspect the inner and outer surfaces of the piston (21) for scoring, wear, or other damage.

N

3. Loosen the packing nut (2) using the wrench (109) supplied.
4. Using a pipe wrench on the hex of the intake cylinder (19), unscrew it from the intake valve housing (17). The pump may separate at joints A, B, or C. See Fig. 8.

05002 Fig. 7

Graco 308351K — N diagram (page 20)
Fig. 4

04993 Fig. 8

17a, b, c ·

Page 21 of the Graco 308351K user manual — T
Page 21 · click to enlarge
Page 21

Displacement Pump Service

6. Pull the intake seat (37) and seal (38) out the bottom of the intake valve housing (17). Take care not to drop the check valve assembly (V) as it comes free, and set it aside for later. See Fig. 7.
Graco 308351K — Displacement Pump Service diagram (page 21)
Fig. 5 · Displacement Pump Service
7. Using a rubber mallet, drive the displacement rod (1) and the priming piston rod (18) out of the outlet housing (9) and cylinder (10). Inspect the outer surfaces of the rods for damage by running a finger over the surface.
8. Unscrew the packing nut (2). Unscrew the packing housing (3) and remove the seal (42). Remove the throat glands and packings (T). See Fig. 10.

THROAT PACKING DETAIL

Graco 308351K — THROAT PACKING DETAIL diagram (page 21)
Fig. 6

T

05002 Model 236611 Displacement Pump Shown

42* ·

Page 22 of the Graco 308351K user manual — DETAIL OF PISTON CHECK VALVE
Page 22 · click to enlarge
Page 22

Displacement Pump Service

9. Remove the seal (8) from the bottom of the cylinder (10). See Fig. 12. Shine a light into the cylinder to examine the inside surface for scoring or damage. Only if the cylinder is damaged, or there is evidence of leaking around the top cylinder seal (8), unscrew the cylinder from the outlet housing, using a pipe wrench. Remove the top cylinder seal.
14. Unscrew the bleeder valve plug (20) completely from the valve body (29). Clean the valve threads and the bleed hole. It is not necessary to remove the valve body from the pump outlet housing (9).
10. Place the flats of the displacement rod (1) in a vise. Unscrew the piston (12) from the displacement rod; the priming piston rod (18) will come with it. Slide the piston guide (11) and seat (14) off the piston (12).
15. Inspect all parts for damage. Clean all parts and threads with a compatible solvent. Reassemble as explained on page 23.
11. It is not necessary to remove the priming piston rod (18) from the piston (12) unless your inspection reveals damage to either part. To disassemble, place the piston flats in a vise and unscrew the rod.
12. Place the piston guide (11) in a vise, as shown in Fig. 11. Using an adjustable wrench, unscrew the piston seat (14) from the guide. Remove the seal (13); always replace it with a new one. Inspect the mating surfaces (M) of the piston (12) and piston seat (14) for damage or wear. See Fig. 12.

When reassembling items 11 and 14, apply thread sealant and torque to approx. 77–85 N.m (57–63 ft-lb).

13. To disassemble the intake check valve assembly (V), place the intake valve body (16) in a vise and unscrew the packing nut (15). Remove the seal (39) from the nut, and the glands and packings (P) from the valve body. Inspect the mating surfaces (N) of the intake valve body (16) and seat (37) for damage or wear. See Figs. 7 and 13.

03832 Fig. 11

DETAIL OF PISTON CHECK VALVE

Torque to 125–139 N.m (92–102 ft-lb).

Torque to 324–368 N.m (239–271 ft-lb).

Lubricate.

17a, b, c M

13* · *8 ·

Page 23 of the Graco 308351K user manual — Reassembly
Page 23 · click to enlarge
Page 23

Displacement Pump Service

Reassembly

4. Lubricate the piston seal (13*) and install it on the piston seat (14). Apply thread sealant to the threads of the seat and the piston guide (11). Screw the guide onto the seat (14). Place the guide in a vise as shown in Fig. 11 and torque the seat to 77–85 N.m (57–63 ft-lb).

Fig. 16 shows a cutaway of the entire pump.

1. Lubricate the intake packings and install them in the valve body (16), with the lips of the v-packings facing up. Install the v-packings in the order shown in Fig. 13.
5. If it was necessary to remove the priming piston rod (18) from the piston (12), place the flats of the piston in a vise. Using an adjustable wrench on the flats of the rod, screw the rod into the piston. Torque to 125–139 N.m (92–102 ft-lb). Be careful not to create burrs on the flats of the rod.
2. With the beveled side facing up, press the intake valve seal (39*) into the recess of the intake valve packing nut (15) until it snaps into place. The nose of the seal should be flush with or slightly recessed into the face of the packing nut.
6. Place the piston seat/guide assembly onto the piston (12) so the 45 beveled seating surfaces match. Screw the displacement rod (1) into the piston (12) hand tight, then torque the rod to 324–368 N.m (239–271 ft-lb).
3. Place the flats of the valve body (16) in a vise. Screw the packing nut into the valve body handtight. Set the intake housing assembly aside.

Lubricate.

Lips of v-packings must face up.

Optional Displacement Pump 237945 uses all PTFE v-packings (item 24).

Model 236611 Displacement Pump Shown

04225 Fig. 13

Show 8 more labels / short text on this page
39* · 23* · 26* · 24* · 26* · 24* · 25* ·
Page 24 of the Graco 308351K user manual — 16 15 V
Page 24 · click to enlarge
Page 24

Displacement Pump Service

7. If the cylinder (10) was removed from the outlet housing (9), lubricate the seal (8*) and place it on the top of the cylinder. (The cylinder is symmetrical, so either end can be the top.) Screw the cylinder into the outlet housing. See Fig. 16.
11. Lubricate the seal (8*) and install it on the bottom of the cylinder (10). Slide the intake valve housing (17) onto the priming piston rod (18), making certain that the smooth surface of the valve stop (VS) is facing down toward the pump intake. Screw the housing onto the cylinder. See Fig. 16.
12. Lubricate the priming piston rod (18), then slide the assembled intake valve (V) onto the rod, making certain that the packing nut (15) goes on the rod first. Push the valve assembly up the rod, stopping before it reaches the intake valve housing (17). See Fig. 14.
8. Lubricate the seal (42*) and install it in the groove on the bottom of the packing housing (3). Screw the packing housing into the outlet housing (9) and torque to 176–258 N.m (130–190 ft-lb). See the Detail in Fig. 16.
13. Hold the valve body (16) steady with a wrench while using an adjustable wrench to tighten the packing nut (15). See Fig. 14. Torque to 97–107 N.m (71–79 ft-lb). Use a rubber mallet on the priming piston rod (18), to drive the valve assembly up to the stop (VS).
9. Lubricate the throat packings and glands, and install them in the packing housing (3) one at a time, with the lips of the v-packings facing down. Install the v-packings in the order shown in the Detail in Fig. 16. Loosely install the packing nut (2).
14. The intake seat (37) is reversible. Inspect both sides of the seat and install it with the best side facing into the housing (17). Push it into the housing until it seats securely. Lubricate the seal (38*) and install in the bevel around the bottom of the seat. See Fig. 16.
10. Lubricate the displacement rod (1). Slide the rod, piston assembly, and priming piston rod (18) into the cylinder (10) from the bottom, until the top of the rod (1) protrudes from the packing nut (2).

16 15 V

Hold valve body (16) steady. Torque packing nut (15) to 97–107 N.m (71–79 ft-lb).

04992 Fig. 14

17a, b, c ·

Page 25 of the Graco 308351K user manual — Displacement Pump Service
Page 25 · click to enlarge
Page 25

Displacement Pump Service

15. Screw the intake cylinder (19) into the intake housing (17). Using a pipe wrench on the hex of the cylinder (19), torque the cylinder to 468–590 N.m (345–435 ft-lb). This will also torque the intake valve housing (17) and pump cylinder (10) into the outlet housing (9). See Fig. 15.
18. Slide the priming piston (21) onto the rod (18) until it stops. Hold the rod (18) steady with an adjustable wrench on the flats, and screw the seat (22) onto the rod with another wrench. Torque to 77–85 N.m (57–63 ft-lb). See Fig.15.
19. Reconnect the displacement pump to the motor as explained on page 19.
16. Screw the bleeder valve plug (20) into the valve body (29). The plug has two sets of threads. When reassembling, be sure to screw the plug completely into the valve body. See Fig. 16.
20. Allow 2 hours for the thread sealant to cure before returning the pump to service.
17. Check that the flats of the priming piston rod (18) are accessible below the intake cylinder (19). If not, tap on the top of the displacement rod (1) with a rubber mallet, until the flats are exposed.

17a, b, c 10

Torque to 77–85 N.m (57–63 ft-lb).

Torque to 468–590 N.m (345–435 ft-lb).

Page 26 of the Graco 308351K user manual — For Pumps 198466, 237265 and 236471 only
Page 26 · click to enlarge
Page 26

Displacement Pump Service

For Pumps 198466, 237265 and 236471 only

THROAT PACKING DETAIL

Graco 308351K — For Pumps 198466, 237265 and 236471 only diagram (page 26)
Fig. 7 · For Pumps 198466, 237265 and 236471 only

Screw valve plug (20) completely into valve body (29).

Optional Displacement Pump 237945 uses all PTFE v-packings (item 4).

·

Page 27 of the Graco 308351K user manual — For Pumps 246938, 246940, 246941 and 246942 only
Page 27 · click to enlarge
Page 27

Displacement Pump Service

For Pumps 246938, 246940, 246941 and 246942 only

Servicing the Throat Packings

3. Place the flats of the packing nut (2) in a vise. Unscrew the packing housing (3) and discard it and the packings. Remove the washer (46), seal (5), and backup washer (45) from the packing nut.
4. The throat repair kit is preassembled. Screw the kit into the packing nut (2), making sure that the backup washer (45*), seal (5*), and washer (46*) are properly positioned on top of the packing housing (3*), with the lips of the seal facing down. Torque the packing housing (3*) to 97–106 N.m (71–78 ft-lb). See Fig. 17.

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page12.

5. Check that the washer (47*) and o-ring (6*) are properly installed on the bottom of the packing housing (3*).
1. Relieve the pressure.
2. See Fig. 17. Unscrew the packing nut (2) using a pipe wrench. Remove the o-ring (6) and washer (47) from the bottom of the packing housing (3) or from the outlet housing (9).
6. Screw the packing nut (2) into the outlet housing (9). Torque to 190–217 N.m (140–160 ft-lb).

Torque to 97–106 N.m (71–78 ft-lb).

Torque to 190–217 N.m (140–160 ft-lb).

Lips of u-cup packing must face down.

Show 8 more labels / short text on this page
45* · 5* · 46* · 5* · 3* · 6* · 47* ·
Page 28 of the Graco 308351K user manual — 04994B
Page 28 · click to enlarge
Page 28

Parts

Part No. 236471 Pump, Series B, 65:1 Ratio, with King Air Motor

Part No. 246942 Pump, Series A, 65:1 Ratio, with King Air Motor

Part No. 237261 Pump, Series A, 31:1 Ratio, with Bulldog Air Motor

Part No. 246940 Pump, Series A, 31:1 Ratio, with Bulldog Air Motor

Part No. 237264 Pump, Series A, 19:1 Ratio, with Senator Air Motor

Part No. 246941 Pump, Series A, 19:1 Ratio, with Senator Air Motor

Part No. 241901 Pump, Series A, 31:1 Ratio, with Bulldog Air Motor

Ref. No. Part No. Description Qty.

101 245111 AIR MOTOR, King Used on Model 236471 and 246942 only. See 309347 for parts. 1 208356 AIR MOTOR, Bulldog Used on Model 237261, 246940 and 241901. See 307049 for parts. 1 217540 AIR MOTOR, Senator Used on Model 237264 and 246941 only. See 307592 for parts. 1 102 190000 ROD, tie; 224 mm (8.82”) shoulder to shoulder 3 190437 ROD, tie; 380 mm (14.96”) shoulder to shoulder Used on Model 241901 only 3 103 106166 NUT, hex; M16 x 2.0 3 104 186925 NUT, coupling 1 105 184129 COLLAR, coupling 2 106 236611 PUMP, displacement See page 34 for parts 1 246939 PUMP, displacement Used on Model 246942, 246940 and 246941 only. See page 32 for parts. 1 109 112887 WRENCH, spanner 1 110 190436 ROD, connecting Used on Model 241901 only 1

04994B

Show 4 more labels / short text on this page
Model 241901 Shown · 105 102 · 104 109 ·
Page 29 of the Graco 308351K user manual — Parts
Page 29 · click to enlarge
Page 29

Parts

Part No. 198475 Pump, Series A, 65:1 Ratio, with Quiet King Air Motor

Ref. No. Part No. Description Qty.

101 235525 AIR MOTOR, Quiet King See 309348 for parts 1 102 198476 ROD, tie; 271 mm (10.67”) shoulder to shoulder 3 103 106166 NUT, hex; M16 x 2.0 3 104 186925 NUT, coupling 1 105 184129 COLLAR, coupling 2 106 198469 PUMP, displacement See page 34 for parts 1 109 112887 WRENCH, spanner 1 110 198465 FITTING, 1” npt 1 111 198477 ADAPTER 1 112 109482 PACKING, o–ring, fluoroelastomer 1 113 198478 KIT, accessory, intake and exhaust 1

Show 4 more labels / short text on this page
105 102 104 · 106 103 · ti1449a ·
Page 30 of the Graco 308351K user manual — Part No. 198466 Pump, Series A, with Viscount II Hydraulic Motor
Page 30 · click to enlarge
Page 30

Parts

Part No. 198466 Pump, Series A, with Viscount II Hydraulic Motor

Part No. 246938 Pump, Series A, with Viscount II Hydraulic Motor

Ref. No. Part No. Description Qty.

101 198468 MOTOR, Viscount II See 307158 for parts 1 102 198471 ROD, tie; 235 mm (9.25”) shoulder to shoulder 3 103 106166 NUT, hex; M16 x 2.0 3 104 186925 NUT, coupling 1 105 184129 COLLAR, grounding 2 106 198469 PUMP, displacement Used on Model 198466 only. See page 34 for parts 1 246939 PUMP, displacement Used on Model 246938 only. See page 32 for parts 1 109 112887 WRENCH, spanner 1 110 198473 FITTING, reducer 1 111 198472 FITTING, reducer 1 112 198465 FITTING, 1” npt 1 113 109482 PACKING, o–ring, fluoroelastomer 1

105 102 · ti1446a ·

Page 31 of the Graco 308351K user manual — 04991B
Page 31 · click to enlarge
Page 31

Parts

Part No. 237265 Pump, Series B, 65:1 Ratio, with Reduced Icing Quiet King Air Motor

Part No. 240945 Pump, Series B, 65:1 Ratio, with Quiet King Air Motor

Part No. 253376 Pump, Series B, 65:1 Ratio, with Quiet King Air Motor

Part No. 237274 Pump, Series A, 31:1 Ratio, with Reduced Icing Quiet Bulldog Air Motor

Ref. No. Part No. Description Qty.

101 245112 AIR MOTOR, Reduced Icing Quiet King Used on Model 237265 only See 309348 for parts 1 220106 AIR MOTOR, Quiet King Used on Models 240945 and 253376 only; See 309348 for parts 1 237001 AIR MOTOR, Reduced Icing Quiet Bulldog Used on Model 237274 only See 307304 for parts 1 102 190000 ROD, tie; 224 mm (8.82”) shoulder to shoulder 3 103 106166 NUT, hex; M16 x 2.0 3 104 186925 NUT, coupling 1 105 184129 COLLAR, coupling 2 106 236611 PUMP, displacement See page 34 for parts 1 237885 PUMP, displacement Used on Model 253376 only See manual 308570 for parts 1 109 112887 WRENCH, spanner 1

04991B

Model 237265 Shown · 102 104 ·

Page 32 of the Graco 308351K user manual — Part No. 246939, Series A,
Page 32 · click to enlarge
Page 32

Displacement Pump Parts

Part No. 246939, Series A,

Ref Part No. No. Description Qty

Ref Part No. No. Description Qty

1 189317 ROD, displacement; stainless steel 1 2 237799 PACKING NUT/WET-CUP; carbon steel 1 3* 190585 HOUSING, throat seal; carbon steel 1 5* 113021 SEAL, u–cup, throat; PTFE with stainless steel spring 2 6* 106258 O–RING; fluoroelastomer 1 8 109499 SEAL, cylinder; PTFE 2 9 237567 HOUSING, outlet; ductile iron 1 10 189437 CYLINDER, pump; stainless steel 1 11 189438 GUIDE, piston; stainless steel 1 12 189439 PISTON; stainless steel 1 13 189440 SEAL, piston; UHMWPE; 1 14 189441 SEAT, piston; stainless steel 1 15 189727 NUT, packing, intake valve; carbon steel 1 16 189514 VALVE BODY, intake; chrome plated stainless steel 1 17a 189442 HOUSING, intake; ductile iron 1 17b 184090 LABEL, warning 1 17c 100508 SCREW, drive 2 18 184400 ROD, priming piston; stainless steel 1 19 189447 CYLINDER, intake; ductile iron 1

20 190128 PLUG, bleeder valve; carbon steel 1 21 276378 PISTON, priming; stainless steel 1 23 184246 GLAND, intake valve, male; carbon steel 1 24 109301 V–PACKING, intake valve; PTFE 2 25 184196 GLAND, intake valve, female; carbon steel 1 26 109251 V–PACKING, intake valve; UHMWPE 2 29 165702 BODY, bleeder valve; carbon steel 1 30 172479 TAG, warning (not shown) 1 37 189446 SEAT, intake valve; chrome plated stainless steel 1 38 189492 SEAL, intake; PTFE 1 39 189724 SEAL, intake valve; UHMWPE; 1 42 166073 SEAL; PTFE 1 43* 195233 WASHER; seal backup 1 44* 195234 WASHER; scraper 1 45* 195232 WASHER; rod scraper 1

* These parts are included in Throat Repair Kit 241782,

which may be purchased separately.

Replacement Danger and Warning labels, tags and cards

are available at no cost.

Page 33 of the Graco 308351K user manual — Displacement Pump Parts
Page 33 · click to enlarge
Page 33

Displacement Pump Parts

Show 9 more labels / short text on this page
*43 · *5 · *44 · *5 · *3 · *45 · *6 20 · 17a, b, c ·
Page 34 of the Graco 308351K user manual — Part No. 236611, 198469 and 237945; Series A
Page 34 · click to enlarge
Page 34

Displacement Pump Parts

Part No. 236611, 198469 and 237945; Series A

Ref Part No. No. Description Qty

Ref Part No. No. Description Qty

1 189317 ROD, displacement; stainless steel 1 2 222995 PACKING NUT/WET-CUP; carbon steel 1 3 189641 HOUSING, throat packing; carbon steel 1 8* 109499 SEAL, cylinder; PTFE 2 9 237567 HOUSING, outlet; ductile iron 1 10 189437 CYLINDER, pump; stainless steel 1 11 189438 GUIDE, piston; stainless steel 1 12 189439 PISTON; stainless steel 1 13* 189440 SEAL, piston; UHMWPE; Used on Models 236611 and 198469 1 190015 SEAL, piston; PTFE; Used on Model 237945 only 1 14 189441 SEAT, piston; stainless steel 1 15 189727 NUT, packing, intake valve; carbon steel 1 16 189514 VALVE BODY, intake; chrome plated stainless steel 1 17a 189442 HOUSING, intake; ductile iron 1 17b 184090 LABEL, warning 1 17c 100508 SCREW, drive 2

18 184400 ROD, priming piston; stainless steel 1 19 189447 CYLINDER, intake; ductile iron 1 198470 CYLINDER, intake; carbon steel Used on Model 198469 1 20 190128 PLUG, bleeder valve; carbon steel 1 21 276378 PISTON, priming; stainless steel 1 22 190241 SEAT, priming piston; stainless steel 1 29 165702 BODY, bleeder valve; carbon steel 1 30 172479 TAG, warning (not shown) 1 37 189446 SEAT, intake valve; chrome plated stainless steel 1 38* 189492 SEAL, intake; PTFE 1 39* 189724 SEAL, intake valve; UHMWPE; Used on Models 236611 and 198469 1 189725 SEAL, intake valve; PTFE; Used on Model 237945 only 1 42* 166073 SEAL; PTFE 1

* These parts are included in the pump repair kit. See page

36 for the applicable kit for your pump.

Replacement Danger and Warning labels, tags and cards

are available at no cost.

Page 35 of the Graco 308351K user manual — Displacement Pump Parts
Page 35 · click to enlarge
Page 35

Displacement Pump Parts

Intake Packing Stack. See page 36.

Throat Packing Stack.

See page 36.

Show 7 more labels / short text on this page
39* · 38* · *8 · *42 · *13 · 17a, b, c ·
Page 36 of the Graco 308351K user manual — THROAT PACKINGS: LIPS FACE DOWN
Page 36 · click to enlarge
Page 36

Displacement Pump Parts

Part No. 236611 and 198469, Series A, Standard UHMWPE/PTFE Packed Displacement Pump

Ref Part No. No. Description Qty

THROAT PACKINGS: LIPS FACE DOWN

INTAKE PACKINGS: LIPS FACE UP

LUBRICATE PACKINGS

4* 109306 V-PACKING, throat; PTFE 2 5* 184201 GLAND, throat, female; carbon steel 1 6* 109256 V-PACKING, throat; UHMWPE 3 7* 184251 GLAND, throat, male; carbon steel 1 23* 184246 GLAND, intake valve, male; carbon steel 1 24* 109301 V-PACKING, intake valve; PTFE 2 25* 184196 GLAND, intake valve, female; carbon steel 1 26* 109251 V-PACKING, intake valve; UHMWPE 2

* These parts are included in Repair Kit 222864, which may

be purchased separately. See page 34 for additional parts included in the kit.

Part No. 237945, Series A, Optional PTFE Packed Displacement Pump

Ref Part No. No. Description Qty

THROAT PACKINGS: LIPS FACE DOWN

INTAKE PACKINGS: LIPS FACE UP

LUBRICATE PACKINGS *5

4* 109306 V-PACKING, throat; PTFE 5 5* 184201 GLAND, throat, female; carbon steel 1 7* 184251 GLAND, throat, male; carbon steel 1 23* 184246 GLAND, intake valve, male; carbon steel 1 24* 109301 V-PACKING, intake valve; PTFE 4 25* 184196 GLAND, intake valve, female; carbon steel 1

* These parts are included in Repair Kit 222865, which may

be purchased separately. See page 34 for additional parts included in the kit.

Show 13 more labels / short text on this page
*5 · *23 · *26 · 24* *25 · *6 · 4* · *7 · *23 · *24 · *4 · *25 · *7 ·
Page 37 of the Graco 308351K user manual — Notes
Page 37 · click to enlarge
Page 37

Notes

Page 38 of the Graco 308351K user manual — (Model 236471 and 246942 King Pumps)
Page 38 · click to enlarge
Page 38

Technical Data

(Model 236471 and 246942 King Pumps)

Be sure that all fluids and solvents used are chemically compatible with the Wetted Parts listed below. Always read the manufacturer’s literature before using fluid or solvent in this pump.

Ratio 65:1

Maximum fluid working pressure 23647140 MPa, 403 bar (5850 psi) 246942 : 48 MPa, 483 bar (7000 psi)
Maximum air input pressure 2364710.6 MPa, 6 bar (90 psi) 246942 : 0.7 MPa, 7 bar (100 psi)

Pump cycles per 3.8 liters (1 gal.) 21

Fluid flow at 60 cycles/min 10.6 liters/min (2.8 gpm)

Air motor piston effective area 506 cm (78.5 in.)

Stroke length 120 mm (4.75 in.)

Displacement pump effective area 8 cm (1.24 in.)

Maximum pump operating temperature 82C (180F)

Air inlet size 3/4 npsm(f)

Fluid outlet size 1” npt(f)

Weight approx. 73 kg (160 lb)

Displacement pump weight approx. 37 kg (81 lb)

Wetted parts Carbon Steel; Chrome, Zinc, and Nickel Plating; 304, 316, 440, and 17–4 PH Grades of Stainless Steel; Alloy Steel; Ductile Iron; PTFE; Glass-Filled PTFE; Ultra-High Molecular Weight Polyethylene

Sound Pressure Levels dB(A) (measured at 1 meter from unit)

Input Air Pressures at 15 cycles per minute

Air Motor 0.3 MPa, 2.8 bar (40 psi) 0.5 MPa, 4.8 bar (70 psi) 0.6 MPa, 6.2 bar (90 psi)

King 78.8 dB(A) 82.7 dB(A) 90.5 dB(A)

Sound Power Levels dB(A) (tested in accordance with ISO 9614–2)

Input Air Pressures at 15 cycles per minute

Air Motor 0.3 MPa, 2.8 bar (40 psi) 0.5 MPa, 4.8 bar (70 psi) 0.6 MPa, 6.2 bar (90 psi)

King 86.5 dB(A) 88.8 dB(A) 97.7 dB(A)

Category Data ·

Page 39 of the Graco 308351K user manual — AIR CONSUMPTION
Page 39 · click to enlarge
Page 39

Technical Data

(Model 236471 and 246942 King Pumps)

Performance Charts

To find Fluid Outlet Pressure (psi/MPa/bar) at a specific fluid flow (lpm/gpm) and operating air pressure (psi/MPa/bar):

To find Pump Air Consumption (m/min or scfm) at a specific fluid flow (lpm/gpm) and air pressure (psi/MPa/bar):

1. Locate desired flow along bottom of chart.
1. Locate desired flow along bottom of chart.
2. Follow vertical line up to intersection with selected fluid outlet pressure curve (black). Follow left to scale to read fluid outlet pressure.
2. Read vertical line up to intersection with selected air consumption curve (dashes). Follow left to scale to read air consumption.

A 0.6 MPa, 6.2 bar (90 psi) air pressure B 0.5 MPa, 4.9 bar (70 psi) air pressure C 0.3 MPa, 2.8 bar (40 psi) air pressure

Test Fluid: No. 10 Weight Oil

21 42 63 psi MPa, bar

21 42 63 scfm m/min

A

AIR CONSUMPTION

FLUID PRESSURE

B

A

B

gpm liters/minute 3.8 7.6 11.4

gpm liters/minute 3.8 7.6 11.4

Test Fluid: 4 Million CPS Weldable Rubber Base Sealer

21 42 63 psi MPa, bar

21 42 63 scfm m/min

AIR CONSUMPTION

FLUID PRESSURE

A

B

A

B

gpm liters/minute 3.8 7.6 11.4

gpm liters/minute 3.8 7.6 11.4

Show 31 more labels / short text on this page
Fluid Outlet Pressure · Air Consumption · cycles per minute · cycles per minute · · · 42, 420 · · · 28, 280 · · · 14, 140 · · · Fluid Outlet Pressure · Air Consumption · cycles per minute · cycles per minute · · · 42, 420 · · · 28, 280 · · · 14, 140 · · ·
Page 40 of the Graco 308351K user manual — (Models 240945, 253376, and 198475 Quiet King Pump and
Page 40 · click to enlarge
Page 40

Technical Data

(Models 240945, 253376, and 198475 Quiet King Pump and

Model 237265 Reduced Icing Quiet King Pump)

Be sure that all fluids and solvents used are chemically compatible with the Wetted Parts listed below. Always read the manufacturer’s literature before using fluid or solvent in this pump.

Ratio 65:1

Maximum fluid working pressure 40 MPa, 403 bar (5850 psi)

Maximum air input pressure 0.6 MPa, 6 bar (90 psi)

Pump cycles per 3.8 liters (1 gal.) 21

Fluid flow at 60 cycles/min 10.6 liters/min (2.8 gpm)

Air motor piston effective area 506 cm (78.5 in.)

Stroke length 120 mm (4.75 in.)

Displacement pump effective area 8 cm (1.24 in.)

Maximum pump operating temperature 82C (180F)

Air inlet size Models 240945, 253376, and 237265: 3/4 npsm(f) Model 198475: G1/2

Fluid outlet size 1” npt(f)

Weight approx. 73 kg (160 lb)

Displacement pump weight approx. 37 kg (81 lb)

Wetted parts Carbon Steel; Chrome, Zinc, and Nickel Plating; 304, 316, 440, and 17–4 PH Grades of Stainless Steel; Alloy Steel; Ductile Iron; PTFE; Glass-Filled PTFE; Ultra-High Molecular Weight Polyethylene Model 253376: See manual 308570

Sound Pressure Levels dB(A) (measured at 1 meter from unit)

Input Air Pressures at 15 cycles per minute

Air Motor 0.3 MPa, 2.8 bar (40 psi) 0.5 MPa, 4.8 bar (70 psi) 0.6 MPa, 6.2 bar (90 psi)

Quiet King 77.9 dB(A) 79.2 dB(A) 87.5 dB(A)

Sound Power Levels dB(A) (tested in accordance with ISO 9614–2)

Input Air Pressures at 15 cycles per minute

Air Motor 0.3 MPa, 2.8 bar (40 psi) 0.5 MPa, 4.8 bar (70 psi) 0.6 MPa, 6.2 bar (90 psi)

Quiet King 85.2 dB(A) 86.6 dB(A) 95.2 dB(A)

Category Data ·

Page 41 of the Graco 308351K user manual — A
Page 41 · click to enlarge
Page 41

Technical Data

(Models 240945, 253376, and 198475 Quiet King Pump and

Model 237265 Reduced Icing Quiet King Pump)

Performance Charts

To find Fluid Outlet Pressure (psi/MPa/bar) at a specific fluid flow (lpm/gpm) and operating air pressure (psi/MPa/bar):

To find Pump Air Consumption (m/min or scfm) at a specific fluid flow (lpm/gpm) and air pressure (psi/MPa/bar):

1. Locate desired flow along bottom of chart.
1. Locate desired flow along bottom of chart.
2. Follow vertical line up to intersection with selected fluid outlet pressure curve (black). Follow left to scale to read fluid outlet pressure.
2. Read vertical line up to intersection with selected air consumption curve (dashes). Follow left to scale to read air consumption.

A 0.6 MPa, 6.2 bar (90 psi) air pressure B 0.5 MPa, 4.9 bar (70 psi) air pressure C 0.3 MPa, 2.8 bar (40 psi) air pressure

Test Fluid: No. 10 Weight Oil

21 42 63 psi MPa, bar

21 42 63 scfm m/min

A

AIR CONSUMPTION

FLUID PRESSURE

B

A

B

gpm liters/minute 3.8 7.6 11.4

gpm liters/minute 3.8 7.6 11.4

Test Fluid: 4 Million CPS Weldable Rubber Base Sealer

21 42 63 psi MPa, bar

21 42 63 scfm m/min

A

AIR CONSUMPTION

FLUID PRESSURE

B

A B C

gpm liters/minute 3.8 7.6 11.4

gpm liters/minute 3.8 7.6 11.4

Show 31 more labels / short text on this page
Fluid Outlet Pressure · Air Consumption · cycles per minute · cycles per minute · · · 42, 420 · · · 28, 280 · · · 14, 140 · · · Fluid Outlet Pressure · Air Consumption · cycles per minute · cycles per minute · · · 42, 420 · · · 28, 280 · · · 14, 140 · · ·
Page 42 of the Graco 308351K user manual — (Model 237261, 246940 and 241901 Bulldog Pumps)
Page 42 · click to enlarge
Page 42

Technical Data

(Model 237261, 246940 and 241901 Bulldog Pumps)

Graco 308351K — (Model 237261, 246940 and 241901 Bulldog Pumps) diagram (page 42)
Fig. 8 · (Model 237261, 246940 and 241901 Bulldog Pumps)

Be sure that all fluids and solvents used are chemically compatible with the Wetted Parts listed below. Always read the manufacturer’s literature before using fluid or solvent in this pump.

Maximum fluid working pressure 21 MPa, 214 bar (3100 psi)

Maximum air input pressure 0.7 MPa, 7 bar (100 psi)

Fluid flow at 60 cycles/min 10.6 liters/min (2.8 gpm)

Air motor piston effective area 248 cm (38 in.)

Displacement pump effective area 8 cm (1.24 in.)

Maximum pump operating temperature 82C (180F)

Wetted parts Carbon Steel; Chrome, Zinc, and Nickel Plating; 304, 316, 440, and 17–4 PH Grades of Stainless Steel; Alloy Steel; Ductile Iron; PTFE; Glass-Filled PTFE; Ultra-High Molecular Weight Polyethylene

Sound Pressure Levels dB(A) (measured at 1 meter from unit)

Graco 308351K — (Model 237261, 246940 and 241901 Bulldog Pumps) diagram (page 42)
Fig. 9 · (Model 237261, 246940 and 241901 Bulldog Pumps)

Bulldog 82.4 dB(A) 87.3 dB(A) 88.5 dB(A) 90.0 dB(A)

Sound Power Levels dB(A) (tested in accordance with ISO 9614–2)

Graco 308351K — (Model 237261, 246940 and 241901 Bulldog Pumps) diagram (page 42)
Fig. 10 · (Model 237261, 246940 and 241901 Bulldog Pumps)

Bulldog 91.6 dB(A) 95.9 dB(A) 97.4 dB(A) 98.1 dB(A)

Page 43 of the Graco 308351K user manual — A
Page 43 · click to enlarge
Page 43

Technical Data

(Model 237261, 246940 and 241901 Bulldog Pump)

Performance Charts

To find Fluid Outlet Pressure (psi/MPa/bar) at a specific fluid flow (lpm/gpm) and operating air pressure (psi/MPa/bar):

To find Pump Air Consumption (m/min or scfm) at a specific fluid flow (lpm/gpm) and air pressure (psi/MPa/bar):

1. Locate desired flow along bottom of chart.
1. Locate desired flow along bottom of chart.
2. Follow vertical line up to intersection with selected fluid outlet pressure curve (black). Follow left to scale to read fluid outlet pressure.
2. Read vertical line up to intersection with selected air consumption curve (dashes). Follow left to scale to read air consumption.

A 0.7 MPa, 7 bar (100 psi) air pressure B 0.5 MPa, 4.9 bar (70 psi) air pressure C 0.3 MPa, 2.8 bar (40 psi) air pressure

Test Fluid: No. 10 Weight Oil

21 42 63 psi MPa, bar

21 42 63 scfm m/min

A

AIR CONSUMPTION

FLUID PRESSURE

B

A

B

gpm liters/minute 3.8 7.6 11.4

gpm liters/minute 3.8 7.6 11.4

Test Fluid: 4 Million CPS Weldable Rubber Base Sealer

20 40 50 psi MPa, bar

scfm m/min

10 30 20 40 50

A

AIR CONSUMPTION

FLUID PRESSURE

B

A

B

gpm liters/minute 3.8 7.6 9.5

5.7 1.9

3.8 7.6 9.5 5.7 1.9

Show 32 more labels / short text on this page
Fluid Outlet Pressure · Air Consumption · cycles per minute · cycles per minute · · · 21, 210 · · · 14, 140 · · · 7, 70 · · · Fluid Outlet Pressure · Air Consumption · cycles per minute · cycles per minute · · · 21, 210 · · · 14, 140 · · · 7, 70 · · · gpm liters/minute ·
Page 44 of the Graco 308351K user manual — (Model 237274 Reduced Icing Quiet Bulldog Pump)
Page 44 · click to enlarge
Page 44

Technical Data

(Model 237274 Reduced Icing Quiet Bulldog Pump)

Graco 308351K — (Model 237274 Reduced Icing Quiet Bulldog Pump) diagram (page 44)
Fig. 11 · (Model 237274 Reduced Icing Quiet Bulldog Pump)

Be sure that all fluids and solvents used are chemically compatible with the Wetted Parts listed below. Always read the manufacturer’s literature before using fluid or solvent in this pump.

Maximum fluid working pressure 21 MPa, 214 bar (3100 psi)

Maximum air input pressure 0.7 MPa, 7 bar (100 psi)

Fluid flow at 60 cycles/min 10.6 liters/min (2.8 gpm)

Air motor piston effective area 248 cm (38 in.)

Displacement pump effective area 8 cm (1.24 in.)

Maximum pump operating temperature 82C (180F)

Wetted parts Carbon Steel; Chrome, Zinc, and Nickel Plating; 304, 316, 440, and 17–4 PH Grades of Stainless Steel; Alloy Steel; Ductile Iron; PTFE; Glass-Filled PTFE; Ultra-High Molecular Weight Polyethylene

Sound Pressure Levels dB(A) (measured at 1 meter from unit)

Graco 308351K — (Model 237274 Reduced Icing Quiet Bulldog Pump) diagram (page 44)
Fig. 12 · (Model 237274 Reduced Icing Quiet Bulldog Pump)

Reduced Icing Quiet Bulldog 81.5 dB(A) 83.6 dB(A) 85.6 dB(A) 85.8 dB(A)

Sound Power Levels dB(A) (tested in accordance with ISO 9614–2)

Graco 308351K — (Model 237274 Reduced Icing Quiet Bulldog Pump) diagram (page 44)
Fig. 13 · (Model 237274 Reduced Icing Quiet Bulldog Pump)

Reduced Icing Quiet Bulldog 90.2 dB(A) 93.5 dB(A) 94.9 dB(A) 93.3 dB(A)

Page 45 of the Graco 308351K user manual — A
Page 45 · click to enlarge
Page 45

Technical Data

(Model 237274 Reduced Icing Quiet Bulldog Pump)

Performance Charts

To find Fluid Outlet Pressure (psi/MPa/bar) at a specific fluid flow (lpm/gpm) and operating air pressure (psi/MPa/bar):

To find Pump Air Consumption (m/min or scfm) at a specific fluid flow (lpm/gpm) and air pressure (psi/MPa/bar):

1. Locate desired flow along bottom of chart.
1. Locate desired flow along bottom of chart.
2. Follow vertical line up to intersection with selected fluid outlet pressure curve (black). Follow left to scale to read fluid outlet pressure.
2. Read vertical line up to intersection with selected air consumption curve (dashes). Follow left to scale to read air consumption.

A 0.7 MPa, 7 bar (100 psi) air pressure B 0.5 MPa, 4.9 bar (70 psi) air pressure C 0.3 MPa, 2.8 bar (40 psi) air pressure

Test Fluid: No. 10 Weight Oil

21 42 63 psi MPa, bar

21 42 63 scfm m/min

A

AIR CONSUMPTION

FLUID PRESSURE

B

A

B

gpm liters/minute 3.8 7.6 11.4

gpm liters/minute 3.8 7.6 11.4

Test Fluid: 4 Million CPS Weldable Rubber Base Sealer

20 40 50 psi MPa, bar

scfm m/min

10 30 20 40 50

A

AIR CONSUMPTION

FLUID PRESSURE

B

A

B

gpm liters/minute 3.8 7.6 9.5

5.7 1.9

3.8 7.6 9.5 5.7 1.9

Show 32 more labels / short text on this page
Fluid Outlet Pressure · Air Consumption · cycles per minute · cycles per minute · · · 21, 210 · · · 14, 140 · · · 7, 70 · · · Fluid Outlet Pressure · Air Consumption · cycles per minute · cycles per minute · · · 21, 210 · · · 14, 140 · · · 7, 70 · · · gpm liters/minute ·
Page 46 of the Graco 308351K user manual — (Model 237264 and 246941 Senator Pumps)
Page 46 · click to enlarge
Page 46

Technical Data

(Model 237264 and 246941 Senator Pumps)

Graco 308351K — (Model 237264 and 246941 Senator Pumps) diagram (page 46)
Fig. 14 · (Model 237264 and 246941 Senator Pumps)

Be sure that all fluids and solvents used are chemically compatible with the Wetted Parts listed below. Always read the manufacturer’s literature before using fluid or solvent in this pump.

Maximum fluid working pressure 15 MPa, 157 bar (2280 psi)

Maximum air input pressure 0.8 MPa, 8.4 bar (120 psi)

Fluid flow at 60 cycles/min 10.6 liters/min (2.8 gpm)

Air motor piston effective area 154 cm (24 in.)

Displacement pump effective area 8 cm (1.24 in.)

Maximum pump operating temperature 82C (180F)

Wetted parts Carbon Steel; Chrome, Zinc, and Nickel Plating; 304, 316, 440, and 17–4 PH Grades of Stainless Steel; Alloy Steel; Ductile Iron; PTFE; Glass-Filled PTFE; Ultra-High Molecular Weight Polyethylene

Sound Pressure Levels dB(A)

(tested at 1 meter from motor)

Graco 308351K — (Model 237264 and 246941 Senator Pumps) diagram (page 46)
Fig. 15 · (Model 237264 and 246941 Senator Pumps)

Standard Senator 84.3 dB(A) 87.8 dB(A) 89.8 dB(A) 91.2 dB(A)

Sound Power Levels dB(A) (tested in accordance with ISO 9614)

Graco 308351K — (Model 237264 and 246941 Senator Pumps) diagram (page 46)
Fig. 16 · (Model 237264 and 246941 Senator Pumps)

Standard Senator 91.6 dB(A) 94.6 dB(A) 96.4 dB(A) 97.3 dB(A)

Page 47 of the Graco 308351K user manual — AIR CONSUMPTION
Page 47 · click to enlarge
Page 47

Technical Data

(Model 237264 and 246941 Senator Pumps)

Performance Charts

To find Fluid Outlet Pressure (psi/MPa/bar) at a specific fluid flow (lpm/gpm) and operating air pressure (psi/MPa/bar):

To find Pump Air Consumption (m/min or scfm) at a specific fluid flow (lpm/gpm) and air pressure (psi/MPa/bar):

1. Locate desired flow along bottom of chart.
1. Locate desired flow along bottom of chart.
2. Follow vertical line up to intersection with selected fluid outlet pressure curve (black). Follow left to scale to read fluid outlet pressure.
2. Read vertical line up to intersection with selected air consumption curve (dashes). Follow left to scale to read air consumption.

A 0.8 MPa, 8.4 bar (120 psi) air pressure B 0.7 MPa, 7 bar (100 psi) air pressure C 0.5 MPa, 4.9 bar (70 psi) air pressure

Test Fluid: No. 10 Weight Oil

21 42 63 psi MPa, bar

21 42 63 scfm m/min

AIR CONSUMPTION

FLUID PRESSURE

A

B

A

B

gpm liters/minute 3.8 7.6 11.4

gpm liters/minute 3.8 7.6 11.4

Test Fluid: 4 Million CPS Weldable Rubber Base Sealer

20 40 50 psi MPa, bar

scfm m/min

10 30 20 40 50

AIR CONSUMPTION

FLUID PRESSURE

A

A

gpm liters/minute 3.8 7.6 9.5

5.7 1.9

3.8 7.6 9.5 5.7 1.9

Show 32 more labels / short text on this page
Fluid Outlet Pressure · Air Consumption · cycles per minute · cycles per minute · · · 21, 210 · · · 14, 140 · · · 7, 70 · · · Fluid Outlet Pressure · Air Consumption · cycles per minute · cycles per minute · · · 21, 210 · · · 14, 140 · · · 7, 70 · · · gpm liters/minute ·
Page 48 of the Graco 308351K user manual — (Model 198466 and 246938 Viscount II Pumps)
Page 48 · click to enlarge
Page 48

Technical Data

(Model 198466 and 246938 Viscount II Pumps)

Be sure that all fluids and solvents used are chemically compatible with the Wetted Parts listed below. Always read the manufacturer’s literature before using fluid or solvent in this pump.

Maximum fluid working pressure 40 MPa, 403 bar (5850 psi)

Maximum hydraulic fluid input pressure 10.3 MPa, 103 bar (1500 psi)

Pump cycles per 3.8 liters (1 gal.) 21

Fluid flow at 60 cycles/min 10.6 liters/min (2.8 gpm)

Hydraulic motor piston effective area 31.6 cm (4.9 in.)

Stroke length 120 mm (4.75 in.)

Displacement pump effective area 8 cm (1.24 in.)

Maximum pump operating temperature 82C (180F)

Hydraulic fluid inlet size G1/2

Fluid outlet size 1” npt(f)

Weight approx. 80 kg (177 lb)

Displacement pump weight approx. 37 kg (81 lb)

Wetted parts Carbon Steel; Chrome, Zinc, and Nickel Plating; 304, 316, 440, and 17–4 PH Grades of Stainless Steel; Alloy Steel; Ductile Iron; PTFE; Glass-Filled PTFE; Ultra-High Molecular Weight Polyethylene

Sound Pressure Levels dB(A) (measured at 1 meter from unit)

Sound Power Levels dB(A) (tested in accordance with ISO 3744)

Input Hydraulic Pressures at 25 cycles/min

Input Hydraulic Pressures at 25 cycles/min

10 MPa, 100 bar (1450 psi)

10 MPa, 100 bar (1450 psi)

Viscount II 88 dB(A)

Viscount II 103 dB(A)

Show 4 more labels / short text on this page
Category Data · Hydraulic Motor · Hydraulic Motor ·
Page 49 of the Graco 308351K user manual — Dimensions and Mounting Hole Layout
Page 49 · click to enlarge
Page 49

Dimensions and Mounting Hole Layout

Graco 308351K — Dimensions and Mounting Hole Layout diagram (page 49)
Fig. 17 · Dimensions and Mounting Hole Layout

Part No. A B C D E F G

Page 50 of the Graco 308351K user manual — Graco Information
Page 50 · click to enlarge
Page 50

Graco Standard Warranty

Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.

This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or sub- stitution of non–Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.

This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.

THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.

Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.

Graco makes no warranty, and disclaims all implied warranties of merchantability and fitness for a particular purpose in connection with accessories, equipment, materials or components sold but not manufactured by Graco. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.

In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.

FOR GRACO CANADA CUSTOMERS The parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnais- sent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés à la suite de ou en rapport, directement ou indirectement, avec les procedures concernées.

Graco Information

TO PLACE AN ORDER, contact your Graco distributor, or call one of the following numbers

to identify the distributor closest to you:

1–800–328–0211 Toll Free 612–623–6921 612–378–3505 Fax

All written and visual data contained in this document reflects the latest product information available at the time of publication.

Graco reserves the right to make changes at any time without notice.

Graco HeadquartersMinneapolis International Offices: Belgium, Korea, China, Japan

GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440–1441 www.graco.com PRINTED IN USA 308351K 05/1995, Revised 03/2006

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
Pump fails to operate.Restricted air or hydraulic line or inade- quate air supply; closed or clogged valves.Clear any obstructions; check that all valves are open; increase pressure. p.17
Pump fails to operate.Obstructed fluid hose or gun/valve; fluid hose ID is too small.Open, clear*; use a hose with a larger ID. p.17
Pump fails to operate.Fluid dried on the displacement rod.Clean; always stop the pump at the bottom of its stroke; keep the wet-cup 1/3 filled with a compat- ible solvent. p.17
Pump fails to operate.Dirty, worn, or damaged motor parts.Clean or repair; see the separate motor manual. p.17
Pump operates, but output low on both strokes.Restricted air or hydraulic line or inade- quate air supply; closed or clogged valves.Clear any obstructions; check that all valves are open; increase pressure. p.17
Pump operates, but output low on both strokes.Obstructed fluid hose or gun/valve; fluid hose ID is too small.Open, clear*; use a hose with a larger ID. p.17
Pump operates, but output low on both strokes.Bleeder valve is open.Close the valve. p.17
Pump operates, but output low on both strokes.Air is leaking into the supply container.Check the ram plate seal. p.17
Pump operates, but output low on both strokes.Fluid is too heavy for pump priming.Use the bleeder valve (see page 13); use a ram. p.17
Pump operates, but output low on both strokes.Held open or worn intake valve or seals.Clear the valve; replace the seals. p.17
Pump operates, but output low on both strokes.Worn packings in the displacement pump.Replace the packings. p.17
Pump operates, but output low on down- stroke.Fluid too heavy for pump priming.Use the bleeder valve (see page 13); use a ram. p.17
Pump operates, but output low on down- stroke.Held open or worn intake valve or seals.Clear the valve; replace the seals. p.17
Pump operates, but output low on upstroke.Held open or worn piston valve or seals.Clear the valve; replace the seals. p.17
Erratic or accelerated pump speed.Exhausted fluid supply.Refill and prime. p.18
Erratic or accelerated pump speed.Fluid is too heavy for pump priming.Use the bleeder valve (see page 13 or 14); use a ram. p.18
Erratic or accelerated pump speed.Held open or worn piston valve or seals.Clear the valve; replace the seals. p.18
Erratic or accelerated pump speed.Held open or worn priming piston.Clear; service. p.18
Erratic or accelerated pump speed.Worn packings in the displacement pump.Replace the packings. p.18

Ask about the Graco 308351K

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Graco 308351K

Be the first to ask — other owners or our team will answer.

Original document

Graco 308351K manual PDF

50 pages·1.1 MB·Automobile Parts·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…