Electric Stimulator E.M.S Scientifically proven instruction manual

than only their pain


Thank you for purchasing the electronic muscle stimulator. Before using the device, please read the user manual. Above all, read the precautions carefully so that you can operate the device correctly. Please keep this instruction manual.
Identification of Parts 1
Functions 2
Use of electrode gel pads 2
Operation 3
Storage/maintenance 7
Specifications 7
Error correction 8
Description of Modes 9
Diagram of the reflex zones of feet 12
Guaranteed card



The principle of our electronic muscle stimulator is that the low frequency current stimulates pain points in the human body and causes muscular contractions or relaxation. When muscle relaxation occurs, a large amount of blood can enter. When muscle restriction occurs, blood containing metabolites is sent out. These types of measures will recycle, which can help speed up circulation and ease pain, swelling, fatigue, and other symptoms.
The expected purpose of our electronic muscle stimulator is to relieve or reduce human muscular pain, swelling, fatigue pain and promote blood circulation.
1. Appropriate to better ABS materials and designs, in accordance with human construction. The device looks very modern and fine. 2. 99 types of electromagnetic wave intensity with a stepless setting will meet the required ideal result in the correct order. 3. 25 minutes automatic time setting 4. There are 25 types of massage modes for the soul and body. Each impulse massage mode improves the various symptoms and eliminates fatigue. 5. All functions can be operated by remote control and are easy to use.
1. The size of the pads is 5.5 x 8.5 cm. 2. Connect the output cable to the electrode gel pads. 3. Then connect the output cable to the electric muscle stimulator. 4. Remove the protective film from gel pads. 5. Attach the electrode gel pads evenly to the skin. 6. Hold the power button for 3 seconds to turn on the device and set stimulation mode and output intensity as you wish (the display shows your chosen mode and level). 7. Keep the pads clean and never expose them to sunlight. 8. If the electrode gel pads are not sufficiently sticky or dirty, clean the pad or take new ones. Do not clean the electrode gel pads with chemicals. 9. After repeated use, the pads must be replaced. Please take new pads if the current pad has not been used within one year.


Before you start using the device, check that it is in its original state: MODE intensity level, SOLE intensity level and time display show zero, MODE display 1. Other values may affect the functioning of the device and lead to inaccurate results.
1. Put your feet on the device. 2. Press the power button for about 3 seconds to turn on the device. The LCD display will light up blue. 3. Then you can adjust the mode by pressing “” and ““ to select different modes. The maximum mode is 25. 4. The intensity can be increased by pressing the buttons “” ” or decreased by pressing of the keys ““ ” . 5. You can set the modes at any time, but once you reset the mode, the intensity is reset to "0". To avoid a user shock from the new mode, the user should reset intensity. 6. To finish the massage, the user can turn off the device by pressing on power button for about 3 seconds.
: Increase the initial intensity of the sole
Select a mode from 25 pre-modified massage modes upward
: Increase the initial intensity of electrodes
: Reduce the initial intensity of the sole
Select a mode from 25 preset massage modes downward
: Reduce the initial intensity of electrodes

It is used mainly in adults and requires energy and intelligence. The following patients can only use this device after consultation with the doctors, otherwise there may be accidents or physical complaints:
1. Patients with extreme impairment and critical disease. 2. Patients with tumor, cancer, hyperthyroidism, tuberculosis-active period, purulent inflammation. 3. Patients with heart disease and at some age. 4. Patients who are nervous have fear of electronic muscle stimulators. 5. Patients suffering from severe diabetes, high fever, skin allergies, traumatic hemorrhage and fractures. 6. Patients with high blood pressure. 7. Patients with abnormal skin diseases. 8. Patients suffering from psychopathy. 9. Patients who are currently undergoing treatment or feel body abnormalities. 10. If the product performance changes as follows: The output level becomes weaker, strong, even no output, the display is not correct, etc. To end the use of the machine and send it back to the manufacturer or professional maintenance office. 11. The Medical Electrical Equipment requires special precautions regarding EMC and must be installed and put into service in accordance with the EMC information contained in attached documents (see page 13-16). 12 Portable and mobile RF communication devices can affect the medical equipment. 13. The use of accessories, converters and cables other than those specified except the converters or cables sold by the manufacturer of the equipment or system as spare parts for internal components may result in increased EMISSION or reduced IMMUNITY of the apparatus or system.
1. It is forbidden to use the patient with an implanted electronic device (e.g. B. a pacemaker) without medical advice. 2. Please note that the stimulator can have an impact on surgical procedures in patients. Follow the doctor’s advice. 3. Do not operate the device in close proximity (e.g. B. 1 m) to short wave or microwave therapy devices, as this can lead to instabilities in the stimulator output. 4. Please note that the following people should follow the doctor’s advice if they want to use the device: pregnant women and those who suffer from tumor, chronic disease, serious illnesses, severe heart disease or mental disorder. 5. Please do not leave the electrodes with metal substances such as bracelet, watch, necklace etc. come into contact. 6. Make sure your skin is clean before using the electrodes.

Explanation of images, symbols, warnings and abbreviations on the device.


1. Wipe the device with a damp cloth or neutral cleaning agent. Do not use explosive liquids such as thinner or gasoline to clean the device. 2. Keep it away from the magnetic field and range of children. 3. Keep the device away from moisture, high temperatures, direct sunlight or splash water. 4. If the electrode pads are not sufficiently adhered or dirty, wipe them with damp cloth or exchange them for new ones. Do not clean the electrode pads with chemicals. 5. The machine must not be rebuilt or repaired on its own, otherwise we the manufacturer will not consider the warranty. 6. If you are not using it for a long time, please remove the batteries from the remote control.
After use, please make a waste classification and divide the components into electrode pads, cardboard boxes and so on.
Model number: AST-300C The apparatus belongs to type BF class II as defined in Section 5.

Rated voltage: 5V DC, 1000 mA power supply by adapter: WT0502400 Rated Voltage: 100-240V nominal input: 0,1A output waveform: square-wave frequency pulse repetition frequencies: 10-100 HZ Maximum amplitude of the output voltage: 72V Software version No: MC0188F-REV-V1.0

Never glue two adhesive pads to each other. Keep the adhesive pads clean and never expose them to high temperatures and direct sunlight.
To protect the gel pads, always place them on the gel-pad protection after use. Do not touch the gel of pads, as it reduces the gel and its function. Do not clean the electrodes with hot water or chemicals.
If the electrode pads are dirty, it may lack adhesive strength and skin can become irritated. If this is the case, pads should be moistened with water and the dirty part wiped. This enables a pad restoration of the adhesive poser. However, if there is too much water it loses its adhesive strength. The best way is to buy another pad.
The electrode contact points have passed the biocompatibility test (test report is SDFY-2006-2623). The test report shows that the device does not cause skin irritation.




shoulder, back muscle pain etc.


waist muscle pain, etc.



Arm numbness, muscle pain etc.


Leg muscle pain, etc.



Cerebellar - Brain-series

Immunity
The AST-300C is intended for use in the electromagnetic environment specified below. The customer or user of the AST-300C must ensure that it is used in such an environment.
The AST-300C uses RF energy only for its internal function. Therefore, RF emissions are very low and it is unlikely that neighboring electronic devices will be disturbed.
HF emissions CISPR 11 Group 1
HF emissions CISPR 11 Class B
The AST-300C is suitable for use in all facilities, including residential buildings and those directly connected to the low voltage public grid that supplies buildings used for residential purposes.
Voltage fluctuations/flicker emissions IEC 61000-3-3

Immunity
The AST-300C is intended for use in the electromagnetic environment specified below. The customer or user of the AST-300C must ensure that it is used in such an environment.
Test level Fulfilment degree Electromagnetic environment - instructions
Floors should be made of wood, concrete or ceramic tiles. If the floor is covered with synthetic material, relative humidity should be at least 30%. Fast electrical transition to IEC 61000-4-4
Electrostatic discharge (ESD) IEC 61000-4-2
± 6 kV Contact to ± 8 kV air
± 6 kV Contact to ± 8 kV air
± 2 kV for power lines
The quality of the network should correspond to that of a typical business or hospital environment.
± 2 kV for power lines
±1 kV line(s) and neutral conductor
The quality of the network should correspond to that of a typical business or hospital environment.
±1 kV line(s) and neutral conductor
± 2 kV line(s) to earth 95% decrease in UT for 0.5 cycles 40% UT (60% dip in ut) for 5 cycles 70% UT (30% decrease in the UT) for 25 cycles 95% decrease in UT for 5s
± 2 kV line(s) to earth 95% decrease in UT for 0.5 cycles 40% UT (60% dip in ut) for 5 cycles 70% UT (30% decrease in the UT) for 25 cycles 95% decrease in UT for 5s
The quality of the network should correspond to that of a typical business or hospital environment.
Voltage dips, short interruptions and voltage fluctuations of the power supply input lines IEC 61000-4-11
If a dip or interruption of the mains voltage occurs, the current of the AST-300C can drop from normal level. You may need to use an uninterruptible power supply or battery.
If image distortions occur, it may be necessary to position the AST-300C image intensifier further away from sources of magnetic fields with mains frequency or to install a magnetic shield. The magnetic field of the mains frequency should be measured at the intended installation location to ensure that it is sufficiently low. NOTE UT is the AC current of the mains voltage before application of test level.
3 A/m 3 A
Overvoltage IEC 61000-4-5 · mains frequency (50/60Hz) · magnetic field

Immunity
The AST-300C is intended for use in the electromagnetic environment specified below. The customer or user of the AST-300C must ensure that it is used in such an environment.
Compliance
Electromagnetic environment -
Test level
Degree
Guidance
3 Vrms 150 kHz to 80 MHz
Portable and mobile RF communication devices should not be used closer to any part of the AST-300C, including cables than the recommended distance calculated from the equation applicable to transmitter frequency. Recommended distance
d=f,2 80 MHz to 800 MHz
Radiated HF 3 V/m 3 V /m d=2.3 80 MHz to 2.5 GMHz IEC 61000-4-3 80 MHzto 2.5 GHz where P is the maximum output power of the transmitter in watts (W) according to the manufacturer of the sender and d is the recommended distance in meters (m).
The field strengths of fixed RF transmitters, as determined by an electromagnetic location survey should be below the matching level in each frequency range.
In the vicinity of devices, interference may occur with the following symbol marked:
Telephones) and land radio, amateur radio, AM and FM radio broadcasting and television broadcasting, cannot theoretically be accurately predicted. In order to assess the electromagnetic environment based on fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength at the location where AST-300C is used exceeds the allowed RF conformity value, then the AST - 300C should be monitored for normal operation verification. If unusual performance characteristics are observed, additional measures may be required e.g. B. a realignment or other location of the AST-300C. b. In the frequency range from 150 kHz to 80 MHz, field strengths should be below 3 V/m.
RF line IEC 61000-4-6 · d=f,2

The AST-300C is intended for use in an electromagnetic environment that controls radiated RF interference. The customer or user of the AST-300C can help to avoid electromagnetic interference by maintaining a minimum distance between portable and mobile RF communication devices (transmitters) and the ast-300 C, as recommended below, depending on maximum output power of the communication device.
150 kHz to 80 MHz 80 MHz to 800 MHz 800 MHz to 2.5 GHz
0.12 0.12 0.23
0.38 0.38 0.73
1 1.2 1.2 2.3
10 3.8 3.8 7.3
100 12 12 23
For transmitters with a maximum output power not listed above, the recommended separation distance d in meters (m) may be estimated from the equation for the frequency of the transmitter where P is the maximum output energy of the sender in watts (W), as specified by the transmitting manufacturer. NOTE 1 At 80 MHz and 800 MHz the distance is for the higher frequency range. NOTE 2 This rule may not apply in all situations. Electromagnetic propagation is influenced by absorption and reflection of structures, objects and persons.

1. We guarantee that the product is insured against all defects for one year from the date of purchase. There is no cost for accessories or maintenance. The prerequisite is that the product be used in accordance with the instructions contained in the user manual. 2. Costs for accessories can only be incurred if components that are older than one year have to be replaced. No maintenance costs are incurred. 3. Please send the defective product to us or a local dealer. We will take care of it immediately.
Valid for the guarantee 1 year after purchase date
Date of purchase:
Address of the consumer:
Name of the consumer:
Consumer's telephone:
Trader name:
Address of the dealer:
Dealer’s telephone:
Description:
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.