Instruction/ maintenance manual of the product CC-HTSTB Heatcraft Refrigeration Products
Go to page of 24
C L I M A T E C O N T R O L C CHTSTB March 2011 Replaces C C-HTSTB, Dec 2008 www .cold y oucancounton.com A I R C O O L E D C O N D E N S I N G U NI T 1 / 2 T O 6 H P I ND OO R A ND O UT DO O R .
2 C H T 030 L 6 C F M odel C ompressor A pplication E quiv . HP T emp . R efrigerant V oltage I dentier C = Climate Control H = Hermetic S = Semi–herm.
3 F eatures & Benets Typic al Outdoor Hermetic Unit Typic al Outdoor Unit with throwaw ay liquid-line lter and sight glass Typic al Outdoor Hermetic Unit with liquid lter drier and sight .
4 Options Electric al options: Outdoor Indoor Stock Adjustable low pr essure contr ol for medium temp . comp . Option Option N/A Air or electric defrost timer only Option Option 1/2-3 HP low temp .
5 HERMETIC COMPRESSORS P erformance Data - High T emperature (R-404A/507) R-404A/507 Model Compressor C apacity BTUH @ 90°F Ambient Suction T empera ture 40°F 35°F CH*005H6 RST45C1E 8,910 8,150 CH*.
6 HERMETIC COMPRESSORS P erformance Data - Extended T emperature (R-404A/507) * = T for Outdoor, N for Indoor , S for Beacon II™ † = RS compressor not suitable for R-507 R-404A/507 Model Compresso.
7 HERMETIC COMPRESSORS P erformance Data - Lo w T emperature (R-404A/507) * = T for Outdoor, N for Indoor , S for Beacon II™ R-404A/507 Model Compressor C apacity BTUH @ 90°F Ambient Suction T empe.
8 HERMETIC COMPRESSORS P erformance Data - Medium & High T emperature (R-22) * = T for Outdoor, N for Indoor , S for Beacon II™ Hermetic C ompressors R-22 Mo del Compr essor Capacity BTUH @ 90°.
9 HERMETIC COMPRESSORS Unit Specications Electrical Data Model Fig . ++ Compressor Connections (ID) Receiver 90% F ull Lbs. F an(s) Dimensions Net Wt. Lbs. Sound Data dBA † Liquid Suction D (In.) W (In.) H (In.) CH*005H2 A AR T82C1 3/8 1/2 6.0 1 28-1/4 23-3/4 17-1/4 135 67 CH*008H2 A RS64C2 3/8 1/2 6.
10 Model Number Part Number Po wer Supply C ompressor Fan Motor MCA MOPD Evap . F an Amps Defrost Heater Amps V olts Ph Hz † RLA LRA Qty . HP FLA Air Elec. Air Elec. CH*040H2B CR53KQ-PFV 208-230 1 60 26.0 140.0 1 1/3 3.5 36.0 48.0 50 60 12.0 35 CH*040H2C CR53KQ- TF5 208-230 3 60 16.
11 * = T for Outdoor, N for Indoor , S for Beacon II™ R-404A/507 Model Compressor C apacity BTUH @ 90°F Ambient Suction T empera ture 40°F 35°F 30°F 25°F 20°F 10°F 0°F -5°F CZ*020M6 ZS15K4E.
12 * = T for Outdoor, N for Indoor , S for Beacon II™ NOTE: The ZF c ompressor comes with liquid injection. R-404A/507 Model Compressor C apacity BTUH @ 90°F Ambient Suction T empera ture 0°F -10.
13 * = T for Outdoor, N for Indoor , S for Beacon II™ R-22 Mo del Compr essor Capacity BTUH @ 90°F Ambient Suc tion T emperature 35°F 30°F 25°F 20°F 10°F CZ*020M6 ZS15K4E 22,080 20,420 18,800 .
14 R-22 Mo del Compr essor Capacity BTUH @ 90°F Ambient Suc tion T emperature 0°F -10°F -15°F -20°F -25°F -30°F -40°F CZ*020L6 ZF06K4E 11,610 9,400 8,380 7,450 6,590 5,840 4,590 CZ*025L6 ZF08K.
15 * = T for Outdoor, N for Indoor , S for Beacon II™ Per UL and NEC, RLA values hav e been calculated by dividing the Maximum Contin uous Current (MC C ) by 1.56. ^ Pow er supplied by customer . † Consult factory for 50 HZ applications . * = T for Outdoor, N for Indoor , S for Beacon II™ ++ = See Dimensional Drawings for details.
16 SEMI-HERMETIC COMPRESSORS P erformance Data - Medium T emperature (R-404A/507) * = T for Outdoor, N for Indoor , S for Beacon II™ R-404A/507 Model Compressor C apacity BTUH @ 90°F Ambient Suctio.
17 SEMI-HERMETIC COMPRESSORS P erformance Data - Lo w T emperature (R-404A/507) * = T for Outdoor, N for Indoor , S for Beacon II™ ^ NRD1-040E Compressor is Single Phase & uses R -404A only.
18 SEMI-HERMETIC COMPRESSORS P erformance Data - Medium and High T emperature (R-22) * = T for Outdoor, N for Indoor , S for Beacon II™ R-22 Mo del Compr essor Capacity BTUH @ 95°F Ambient Suc tion.
19 SEMI-HERMETIC COMPRESSORS Unit Specications * = T for Outdoor, N for Indoor , S for Beacon II™ ++ = See Dimensional Drawings for details. † = Estimated sound pressure v alues are 10 feet from the unit.
20 SEMI-HERMETIC COMPRESSORS Electrical Data - Medium and High T emperature * = T for Outdoor, N for Indoor , S for Beacon II™ ^ Pow er supplied by customer . † Consult factory for 50 HZ applications. Model Number Part Number Pow er Supply Compr essor Fan Motor MC A MOPD Evap .
21 SEMI-HERMETIC COMPRESSORS Electrical Data - Low T emperature * = T for Outdoor, N for Indoor , S for Beacon II™ ^ Pow er supplied by customer . † Consult factory for 50 HZ applications. NOTE: P er UL and NEC, RLA values have been c alculated by dividing the Maximum Continuous Current (MC C ) by 1.
22 Dimensional Dra wings of Cabinets OUTDOOR A B C D 1/2, 3/4 AND 1HP 1-1/2 AND 2HP 3HP - AL TERNA TE CABINET 3, 4, 5 AND 6HP AIR FLOW AIR FLOW AIR FLOW AIR FLOW SUCTION LIQUID LIQUID SUCTION LIQUID L.
23 A B C D INDOOR 1/2, 3/4 AND 1HP 1-1/2 AND 2HP 3HP - AL TERNA TE CABINET 3, 4, 5 AND 6HP AIR FLOW AIR FLOW AIR FLOW AIR FLOW SUCTION LIQUID LIQUID SUCTION LIQUID LIQUID SUCTION FRONT VIE W OUTDOOR I.
A Brand of Heatcraft Refrigeration P roducts, LL C 2175 West P ar k Place Blv d. • Stone Mountain, GA • 30087 (800) 321-1881 ww w .heatcraftrpd.com C L I M A T E C O N T R O L Cold Y ou Can Count On Since produ ct improvem ent is a continuing eo rt, we rese rve the ri ght to make change s in specicati ons without noti ce.
An important point after buying a device Heatcraft Refrigeration Products CC-HTSTB (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Heatcraft Refrigeration Products CC-HTSTB yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Heatcraft Refrigeration Products CC-HTSTB - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Heatcraft Refrigeration Products CC-HTSTB you will learn all the available features of the product, as well as information on its operation. The information that you get Heatcraft Refrigeration Products CC-HTSTB will certainly help you make a decision on the purchase.
If you already are a holder of Heatcraft Refrigeration Products CC-HTSTB, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Heatcraft Refrigeration Products CC-HTSTB.
However, one of the most important roles played by the user manual is to help in solving problems with Heatcraft Refrigeration Products CC-HTSTB. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Heatcraft Refrigeration Products CC-HTSTB along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center