EN Operators Guide Solution 880 CC408.
CC408 | Operators Guide | Notices EN | 2 Bosch Security Systems | 5/04 | 920050O.OG.112 Copyright Notice Unless otherwise indicated, this publication is the copyright of Bosch Security Systems Pty Ltd (“ Bosch ”). All rights are reserved. You may download a single copy of this publication.
CC408 | Operators Guide | Contents EN | 3 Bosch Security Systems | 5/04 | 920050O.OG.112 Contents 1. Introduction ...................................................... 5 2. Specifications .................................................... 5 3. Features .
CC408 | Operators Guide | Contents EN | 4 Bosch Security Systems | 5/04 | 920050O.OG.112 Tables Table 1: Specifications ............................................. 5 Table 2: Zone Indicator ........................................... 6 Table 3: AWAY Indicator .
CC408 | Operators Guide | 1. Introduction EN | 5 Bosch Security Systems | 5/04 | 920050O.OG.112 1 . Int roduct ion Congratulations on selecting the Solution 880 Model CC408 Control Panel to protect you and your property.
CC408 | Operators Guide | 4. Codepad Indicators EN | 6 Bosch Security Systems | 5/04 | 920050O.OG.112 4. Codepad Indic at ors Figure 1: CP5 Eight Zone LED Codepad Figure 2: CP5 Eight Zone LCD Codepad The codepad is the communications interface between you and your alarm system.
CC408 | Operators Guide | 5. Arming the System EN | 7 Bosch Security Systems | 5/04 | 920050O.OG.112 4.5 MAINS Indicator The MAINS indicator displays the systems AC mains supply is normal or failed. Table 5: MAINS Indicator MAINS Indicator Definition On AC mains power normal.
CC408 | Operators Guide | 5. Arming the System EN | 8 Bosch Security Systems | 5/04 | 920050O.OG.112 Forced Arming The feature of arming the system when a zone is not sealed is known as forced arming. If the system does not arm and a long beep is heard, forced arming is not permitted.
CC408 | Operators Guide | 6. Disarming the System EN | 9 Bosch Security Systems | 5/04 | 920050O.OG.112 Arming in STAY Mode 2 Hold down the [0] button until two beeps sound. The STAY indicator lights and exit time starts counting. Any zones programmed to be automatically isolated in STAY Mode 2 flash until exit time expires.
CC408 | Operators Guide | 8. Radio Transmitter Operations EN | 10 Bosch Security Systems | 5/04 | 920050O.OG.112 8. Radio T ransmitt er Operat ions Figure 3: RE012/E – 2 Channel Keyfob Transmitter 1.
CC408 | Operators Guide | 10. Isolating Zones EN | 11 Bosch Security Systems | 5/04 | 920050O.OG.112 9.3 Fire Alarm The horn speaker emits a distinct fire sound when both the [4] and [6] keys are pressed simultaneously. Contact your installer to disable the ability to activate the codepad fire alarm or to silence the codepad fire alarm.
CC408 | Operators Guide | 12. Fault Analysis Mode EN | 12 Bosch Security Systems | 5/04 | 920050O.OG.112 1 2. F ault Analysis Mode If a fault occurs, the FAULT or MAINS indicators flash and the codepad beeps once every minute. 12.1 AC Fail If the AC mains supply fails, the MAINS indicator flashes until the AC mains supply is restored.
CC408 | Operators Guide | 13. Telco Arm/Disarm Sequence (Call Forward On/Off) EN | 13 Bosch Security Systems | 5/04 | 920050O.OG.112 13 . T e l c o A r m / D i s a r m Sequence ( Call Forward On/Off ) Use this feature to program the Telco Arm Sequence and Telco Disarm Sequence (Call Forward On/Off).
CC408 | Operators Guide | 14. Turning Outputs On/Off EN | 14 Bosch Security Systems | 5/04 | 920050O.OG.112 1 4. T urning Out put s On/Off This feature only applies if your installer set up an output that can be turned on or off by the codepad. The output programmed by your installer can control a pool pump, outside lighting, and so on.
CC408 | Operators Guide | 18. Event Memory Recall EN | 15 Bosch Security Systems | 5/04 | 920050O.OG.112 1 8. Event Memory Rec all Use this function to replay the last 40 events that occurred to the system. The event memory history replays all alarms and arming/disarming of the system in AWAY Mode, STAY Mode 1, and STAY Mode 2.
CC408 | Operators Guide | 21. Domestic Dialling EN | 16 Bosch Security Systems | 5/04 | 920050O.OG.112 2 1 . Domest ic Dialling Domestic dialling is used to call your mobile phone or a relative/friend in the event your control panel activates an alarm.
CC408 | Operators Guide | 22. Partitioning EN | 17 Bosch Security Systems | 5/04 | 920050O.OG.112 22. Partit ioning You can partition or split the Solution 880 Control Panel into two individual areas. You can operate both areas from one Master Partitioned codepad or from separate area addressable codepads.
CC408 | Operators Guide | 23. Basic Pager Reporting EN | 18 Bosch Security Systems | 5/04 | 920050O.OG.112 23. Basic Pager Report ing This feature only applies if your system reports to a pocket pager. Basic pager reporting requires some interpretation of the numbers that appear on the display.
CC408 | Operators Guide | 23. Basic Pager Reporting EN | 19 Bosch Security Systems | 5/04 | 920050O.OG.112 Figure 7: Basic Pager Display 6 7 8 0 1 200000 9000 123456 8 7 1 2 3 4 5 6 7 8 1 – Subscrib.
CC408 | Operators Guide | 24. Glossary of Terms EN | 20 Bosch Security Systems | 5/04 | 920050O.OG.112 24. Glossary of T erms Table 15: Glossary of Terms Term Description 24-Hour Zones A monitored input programmed to trigger an alarm condition when violated when the system is armed or disarmed 24 hours a day.
CC408 | Operators Guide | 24. Glossary of Terms EN | 21 Bosch Security Systems | 5/04 | 920050O.OG.112 Table 15: continued Term Description Silent Alarm Your installer may program zones for silent operation.
CC408 | Operators Guide | 25. Installation Notes EN | 22 Bosch Security Systems | 5/04 | 920050O.OG.112 2 5 . I n s tal la tio n N o te s Company Name Technician’s Name Technician’s Telephone Numb.
CC408 | Operators Guide | 25. Installation Notes EN | 23 Bosch Security Systems | 5/04 | 920050O.OG.112 Zone Description Describe each zone and mark the zones that are programmed to be automatically isolated in STAY Mode 1 or are programmed for day alarm operation.
CC408 | Operators Guide | 25. Installation Notes EN | 24 Bosch Security Systems | 5/04 | 920050O.OG.112 Entry/Exit Times Entry Timer 1 Exit Time Entry Timer 2 Entry Guard Time Arming Options Single Bu.
CC408 | Operators Guide | Index EN | 25 Bosch Security Systems | 5/04 | 920050O.OG.112 Index 24-Hour Zones 20 A AC Mains Fail 12 Adding Radio User Codes 9 Adding User Codes 9 Alarm Condition 20 Alarms Duress ...........................................
CC408 | Operators Guide | Index EN | 26 Bosch Security Systems | 5/04 | 920050O.OG.112 M MAINS Indicator 6, 17 Master Code 20 Master Partitioned Codepad Indicators 17 Medical Alarm 11 Monitoring Stati.
CC408 | Operators Guide | Notes EN | 27 Bosch Security Systems | 5/04 | 920050O.OG.112 Notes:.
© 2003 Bosch Security Systems S1920050 Issue 112 4998152467B Bosch Security Systems 25 Huntingwood Drive Huntingwood NSW 2148 Australia Phone: +612 9672 1777 Facsimile: +612 9672 1717.
An important point after buying a device Bosch Appliances CC408 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Bosch Appliances CC408 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Bosch Appliances CC408 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Bosch Appliances CC408 you will learn all the available features of the product, as well as information on its operation. The information that you get Bosch Appliances CC408 will certainly help you make a decision on the purchase.
If you already are a holder of Bosch Appliances CC408, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Bosch Appliances CC408.
However, one of the most important roles played by the user manual is to help in solving problems with Bosch Appliances CC408. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Bosch Appliances CC408 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center