Contentsp.5About This Manualp.7Conventions, Formats and Scopep.7How to Use This Manualp.8How to Print this Manualp.8Chapter 1 Connecting the Gateway to the Internetp.11Package Contentsp.11Front Panelp.11Rear Panelp.13What You Need Before You Beginp.13Hardware Requirementsp.13LAN Configuration Requirementsp.14Internet Configuration Requirementsp.14Connecting the CG814WG v3 Gatewayp.14Installationp.14Chapter 2 Wireless Configurationp.19Wireless Placement and Range Guidelinesp.20SSID and Wireless Security Settings Formp.21Viewing or Changing Wireless Settingsp.22Turning on Access Control to Restrict Access by MAC Addressp.24How to Configure WEP (Wired Equivalent Privacy)p.26How to Configure WPAp.28Chapter 3 Content Filtering and Firewall Rulesp.31Content Filteringp.31Logsp.32Blocking Keywords, Sites, and Servicesp.32Blocking Keywords and Domainsp.33Servicesp.34Firewall Rulesp.35Port Forwardingp.36Port Blockingp.37Chapter 4 Managing Your Networkp.39Maintenancep.39Gateway Statusp.40Signal Statusp.41Set Passwordp.42Backup Settingsp.43Event Logp.44Advanced Settingsp.45WAN Setupp.45Dynamic DNSp.46LAN IP Settingsp.47Diagnosticsp.48Remote Management Accessp.49UPnPp.50Chapter 5 Troubleshootingp.53Basic Functionsp.53Using LEDs to Troubleshootp.54Connecting to the Gateway’s Main Menup.54Troubleshooting the ISP Connectionp.55Troubleshooting a TCP/IP Network Using a Ping Utilityp.56Testing the LAN Path to Your Gatewayp.56Testing the Path from Your PC to a Remote Devicep.57Appendix A Technical Specifications and Factory Default Settingsp.59Technical Specificationsp.59Factory Default Settingsp.60Appendix B Related Documentsp.63
Page 1 of the NETGEAR Cable Modem Router (CG814WG V3) user manual
Page 1 · click to enlarge
Page 1
NETGEAR Cable Modem Router (CG814WG V3) diagram (page 1)
Fig. 1

NETGEAR, Inc. 4500 Great America Parkway Santa Clara, CA 95054 USA

202-10297-01 June 2007

Page 2 of the NETGEAR Cable Modem Router (CG814WG V3) user manual
Page 2 · click to enlarge
Page 2

© 2007 by NETGEAR, Inc. All rights reserved.

NETGEAR is a trademark of NETGEAR, Inc. Microsoft, Windows, and Windows NT are registered trademarks of Microsoft Corporation. Other brand and product names are registered trademarks or trademarks of their respective holders.

In the interest of improving internal design, operational function, and/or reliability, NETGEAR reserves the right to make changes to the products described in this document without notice.

NETGEAR does not assume any liability that may occur due to the use or application of the product(s) or circuit layout(s) described herein.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

(1) this device may not cause harmful interference, and

(2) this device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.

This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter.

To maintain compliance with FCC’s RF exposure guidelines, this equipment should be installed and operated with minimum distance of 20 cm between the radiator and your body. Use the supplied antenna.

Declaration of Conformity for R&TTE directive 1999/5/EC

Essential requirements – Article 3. Protection requirements for health and safety – Article 3.1a. Testing for electric safety according to EN 60950-1 has been conducted. These are considered relevant and sufficient. Protection

Show 5 more labels / short text on this page
Trademarks · Statement of Conditions · FCC Warning Statement · Prohibition of Co-location · Safety Information
Page 3 of the NETGEAR Cable Modem Router (CG814WG V3) user manual
Page 3 · click to enlarge
Page 3

requirements for electromagnetic compatibility – Article 3.1b. Testing for electromagnetic compatibility according to EN 301 489-1 and EN 301 489-17 has been conducted. These are considered relevant and sufficient. Effective use of the radio spectrum – Article 3.2. Testing for radio test suites according to EN 300 328- 2 has been conducted. These are considered relevant and sufficient.

Es wird hiermit bestätigt, daß das CG814WG v3 Wireless Cable Modem Gateway gemäß der im BMPT-AmtsblVfg 243/ 1991 und Vfg 46/1992 aufgeführten Bestimmungen entstört ist. Das vorschriftsmäßige Betreiben einiger Geräte (z.B. Testsender) kann jedoch gewissen Beschränkungen unterliegen. Lesen Sie dazu bitte die Anmerkungen in der Betriebsanleitung.

Das Bundesamt für Zulassungen in der Telekommunikation wurde davon unterrichtet, daß dieses Gerät auf den Markt gebracht wurde und es ist berechtigt, die Serie auf die Erfüllung der Vorschriften hin zu überprüfen.

Certificate of the Manufacturer/Importer

It is hereby certified that the CG814WG v3 Wireless Cable Modem Gateway has been suppressed in accordance with the conditions set out in the BMPT-AmtsblVfg 243/1991 and Vfg 46/1992. The operation of some equipment (for example, test transmitters) in accordance with the regulations may, however, be subject to certain restrictions. Please refer to the notes in the operating instructions.

Federal Office for Telecommunications Approvals has been notified of the placing of this equipment on the market and has been granted the right to test the series for compliance with the regulations.

Thank you for choosing Netgear product(s). Please register online and take advantage of the technical support resources such as Netgear online knowledge base. Technical support is available 24 hours a day, seven days a week; please call your Cable Internet Service Provider.

Product and Publication Details

Model NumberCG814WG v3
Publication DateJune 2007
Product FamilyProduct Family
Product NameCG814WG v3 Wireless Cable Modem Gateway
Home or Business ProductHome
LanguageEnglish
Publication Part Number202-10297-01

Bestätigung des Herstellers/Importeurs · Technical Support

Page 4 of the NETGEAR Cable Modem Router (CG814WG V3) user manual
Page 4 · click to enlarge
Page 4
Page 4 of the NETGEAR Cable Modem Router (CG814WG V3) user manual
Page 5 of the NETGEAR Cable Modem Router (CG814WG V3) user manual — Table of Contents
Page 5 · Contents
Contents

Contents

Contentsp.5About This Manualp.7Conventions, Formats and Scopep.7How to Use This Manualp.8How to Print this Manualp.8Chapter 1 Connecting the Gateway to the Internetp.11Package Contentsp.11Front Panelp.11Rear Panelp.13What You Need Before You Beginp.13Hardware Requirementsp.13LAN Configuration Requirementsp.14Internet Configuration Requirementsp.14Connecting the CG814WG v3 Gatewayp.14Installationp.14Chapter 2 Wireless Configurationp.19Wireless Placement and Range Guidelinesp.20SSID and Wireless Security Settings Formp.21Viewing or Changing Wireless Settingsp.22Turning on Access Control to Restrict Access by MAC Addressp.24How to Configure WEP (Wired Equivalent Privacy)p.26How to Configure WPAp.28Chapter 3 Content Filtering and Firewall Rulesp.31Content Filteringp.31Logsp.32Blocking Keywords, Sites, and Servicesp.32Blocking Keywords and Domainsp.33Servicesp.34Firewall Rulesp.35Port Forwardingp.36Port Blockingp.37Chapter 4 Managing Your Networkp.39Maintenancep.39Gateway Statusp.40Signal Statusp.41Set Passwordp.42Backup Settingsp.43Event Logp.44Advanced Settingsp.45WAN Setupp.45Dynamic DNSp.46LAN IP Settingsp.47Diagnosticsp.48Remote Management Accessp.49UPnPp.50Chapter 5 Troubleshootingp.53Basic Functionsp.53Using LEDs to Troubleshootp.54Connecting to the Gateway’s Main Menup.54Troubleshooting the ISP Connectionp.55Troubleshooting a TCP/IP Network Using a Ping Utilityp.56Testing the LAN Path to Your Gatewayp.56Testing the Path from Your PC to a Remote Devicep.57Appendix A Technical Specifications and Factory Default Settingsp.59Technical Specificationsp.59Factory Default Settingsp.60Appendix B Related Documentsp.63
Page 7 of the NETGEAR Cable Modem Router (CG814WG V3) user manual — Conventions, Formats and Scope
Page 7 · click to enlarge
Page 7

About This Manual

The NETGEAR® CG814WG v3 Wireless Cable Modem Gateway Reference Manual describes how to install, configure and troubleshoot the CG814WG v3 Wireless Cable Modem Gateway. The information in this manual is intended for readers with intermediate computer and Internet skills.

Conventions, Formats and Scope

The conventions, formats, and scope of this manual are described in the following paragraphs:

  • Typographical Conventions. This manual uses the following typographical conventions:
ItalicsEmphasis, books, CDs, URL names BoldUser input FixedScreen text, file and server names, extensions, commands, IP addresses
  • Formats. This manual uses the following formats to highlight special messages:

equipment.

Page 8 of the NETGEAR Cable Modem Router (CG814WG V3) user manual — How to Print this Manual
Page 8 · click to enlarge
Page 8
  • Scope. This manual is written for the CG814WG v3 Gateway according to these specifications:
Product VersionCG814WG v3 Wireless Cable Modem Gateway Manual Publication DateJune 2007

For more information about network, Internet, firewall, and VPN technologies, see the links to the NETGEAR website in Appendix B, “Related Documents”.

http://kbserver.netgear.com.

How to Use This Manual

The HTML version of this manual includes the following:

  • Buttons, and , for browsing forwards or backwards through the manual one page at a time
  • A button that displays the table of contents and an button. Double-click on a link in the table of contents or index to navigate directly to where the topic is described in the manual.
  • A button to access the full NETGEAR, Inc. online knowledge base for the product model.
  • Links to PDF versions of the full manual and individual chapters.

How to Print this Manual

To print this manual you can choose one of the following several options, according to your needs.

  • Printing a Page in the HTML View .

Each page in the HTML version of the manual is dedicated to a major topic. Use the Print button on the browser toolbar to print the page contents.

  • Printing a Chapter .

Use the PDF of This Chapter link at the top left of any page.

iv About This Manual

Page 9 of the NETGEAR Cable Modem Router (CG814WG V3) user manual — How to Use This Manual
Page 9 · click to enlarge
Page 9

– Click the PDF of This Chapter link at the top left of any page in the chapter you want to print. The PDF version of the chapter you were viewing opens in a browser window. – Your computer must have the free Adobe Acrobat reader installed in order to view and print PDF files. The Acrobat reader is available on the Adobe website at http://www.adobe.com. – Click the print icon in the upper left of the window.

save paper and printer ink by selecting this feature.

  • Printing the Full Manual .

Use the Complete PDF Manual link at the top left of any page.

– Click the Complete PDF Manual link at the top left of any page in the manual. The PDF version of the complete manual opens in a browser window.

– Click the print icon in the upper left of the window.

save paper and printer ink by selecting this feature.

About This Manual v

Page 10 of the NETGEAR Cable Modem Router (CG814WG V3) user manual — How to Use This Manual
Page 10 · click to enlarge
Page 10

vi About This Manual

Page 11 of the NETGEAR Cable Modem Router (CG814WG V3) user manual — Front Panel
Page 11 · click to enlarge
Page 11

Chapter 1 Connecting the Gateway to the Internet

This chapter describes how to set up the CG814WG v3 Gateway on your Local Area Network (LAN), connect to the Internet, and perform basic configuration.

Package Contents

  • The product package should contain the following items:
  • CG814WG v3 Wireless Cable Modem Gateway
  • AC power adapter
  • Category 5 (CAT5) Ethernet cable
  • USB cable

If any of the parts are incorrect, missing, or damaged, contact your NETGEAR dealer. Keep the carton, including the original packing materials, in case you need to return the product for repair.

Front Panel

The front panel of the CG814WG v3 contains status LEDs.

NETGEAR Cable Modem Router (CG814WG V3) — Front Panel diagram (page 11)
Fig. 2 · Front Panel
Page 12 of the NETGEAR Cable Modem Router (CG814WG V3) user manual — Chapter 1 Connecting the Gateway to the Internet
Page 12 · click to enlarge
Page 12

You can use the LEDs to verify connections. Table 1-1 lists and describes each LED on the front panel of the CG814WG v3 Gateway.

Table 1-1. LED Descriptions

LEDDescription Power• On: Power is supplied to the gateway. • Off: Power is not supplied to the gateway. Cable Link• On (green): Configuration of the cable interface by your cable service provider is complete. • Off: Configuration of the cable interface is still in progress. Upstream Traffic• Blink: Data is being transmitted to the cable interface. • Off: The cable interface is idle. Downstream Traffic• Blink: Data is being received from the cable interface. • Off: The cable interface is idle. Wireless• On: The wireless Access Point is operating normally. Blink: Data is being transmitted or received on the wireless interface. LAN (Local Area Network)• On (green): The port has detected link with a 100 Mbps device. • Blink (green): Data is being transmitted or received at 100 Mbps. • On (yellow): The Local port has detected link with a 10 Mbps device. • Blink (yellow): Data is being transmitted or received at 10 Mbps. • Off: No link is detected on this port.

1-2 Connecting the Gateway to the Internet

Page 13 of the NETGEAR Cable Modem Router (CG814WG V3) user manual — Hardware Requirements
Page 13 · click to enlarge
Page 13

Rear Panel

The rear panel of the CG814WG v3 contains the connections identified below:

NETGEAR Cable Modem Router (CG814WG V3) — Rear Panel diagram (page 13)
Fig. 3 · Rear Panel

coaxial cable to your cable service provider

4 Ethernet LAN ports

AC power adapter input

What You Need Before You Begin

  • You need these three things before you can connect your gateway to the Internet:
  • A computer properly connected to the gateway as explained below.
  • Active Data Over Cable Internet service provided by cable modem account.
  • The Internet Service Provider (ISP) configuration information for your cable modem account.

Hardware Requirements

The CG814WG v3 Gateway connects to your LAN using either its twisted-pair Ethernet, USB or 802.11b or 802.11g wireless port.

To use the CG814WG v3 Gateway on your network, each computer must have either an installed Ethernet Network Interface Card (NIC), USB Host port or 802.11b or 802.11g wireless adapter. If the computer will connect to your network at 100 Mbps, you must use a Category 5 (CAT5) cable such as the one provided with your gateway.

Connecting the Gateway to the Internet 1-3

wireless antenna · USB port · reset button

Page 14 of the NETGEAR Cable Modem Router (CG814WG V3) user manual — Installation
Page 14 · click to enlarge
Page 14

LAN Configuration Requirements

For the initial connection to the Internet and configuration of your gateway, connect a computer to the gateway which is set to automatically get its TCP/IP configuration from the gateway via DHCP.

Networking and TCP/IP Addressing” in Appendix B.

Internet Configuration Requirements

  • Depending on how your ISP set up your Internet account, you will need one or more of these configuration settings to connect your gateway to the Internet:
  • Host and Domain Names
  • ISP Domain Name Server (DNS) Addresses
  • Fixed or Static IP Address

Connecting the CG814WG v3 Gateway

connection to your computer first. Then configure the wireless settings. See Chapter 2, “Wireless Configuration” for instructions for wireless settings.

Installation

Follow these steps to install your gateway:

1. Connect the gateway.

a. Turn off your computer.

1-4 Connecting the Gateway to the Internet

Page 15 of the NETGEAR Cable Modem Router (CG814WG V3) user manual — B
Page 15 · click to enlarge
Page 15

b. Using the coaxial cable provided by your cable company, connect the CG814WG v3 cable port (A) to your cable line splitter or outlet.

NETGEAR Cable Modem Router (CG814WG V3) — LAN Configuration Requirements diagram (page 15)
Fig. 4 · LAN Configuration Requirements

A

c. Connect the gateway to your computer with either an Ethernet or USB cable.

Windows 95 does not support USB without special operating system upgrades and patches.

For an Ethernet connection, use the Ethernet cable that shipped with your gateway to connect a LAN port (B) to the Ethernet adapter in your computer.

NETGEAR Cable Modem Router (CG814WG V3) — A diagram (page 15)
Fig. 5

B

Connecting the Gateway to the Internet 1-5

Page 16 of the NETGEAR Cable Modem Router (CG814WG V3) user manual — LAN Configuration Requirements
Page 16 · click to enlarge
Page 16

Ethernet port senses whether the cable plugged into the port is attached to a PC, or is attached to a switch or hub, which requires an uplink connection. The port configures itself to accommodate either type of cable. This eliminates the need for crossover cables.

For a USB connection, connect the USB cable to the USB port on your modem and to a USB port on your computer.

d. Connect the power adapter to the CG814WG v3, and plug it into an outlet.

e. Turn on your computer. If software usually logs you in to your Internet connection, do not run that software or cancel it if it starts automatically.

f. Wait about 30 seconds for the lights to stop blinking, and then verify the following:

The power light is lit after turning on the gateway.

The cable link light is solid green, indicating a link has been established to the cable network.

The LAN lights are lit for any connected computers.

2. For an Ethernet connection, go to Step 3. For a USB connection, install the USB driver.

a. For a USB connection you must install the USB driver. Insert the NETGEAR CD that came with your gateway into the CD drive of your computer.

The Found New Hardware Wizard detects the gateway and prompts for the driver.

NETGEAR Cable Modem Router (CG814WG V3) — LAN Configuration Requirements diagram (page 16)
Fig. 6 · LAN Configuration Requirements

1-6 Connecting the Gateway to the Internet

Page 17 of the NETGEAR Cable Modem Router (CG814WG V3) user manual — LAN Configuration Requirements
Page 17 · click to enlarge
Page 17

b. Browse to the Resource CD and install the USB driver by clicking through the Windows wizard prompts.

3. Log in to the Gateway

address automatically via DHCP. For instructions on how to do this, see the link to “Preparing a Computer for Network Access” in Appendix B.

a. Using the computer that you first used to access your cable modem Internet service, connect to the gateway by typing http://192.168.0.1 in the address field of your Internet browser. A login window opens.

NETGEAR Cable Modem Router (CG814WG V3) — LAN Configuration Requirements diagram (page 17)
Fig. 7 · LAN Configuration Requirements
NETGEAR Cable Modem Router (CG814WG V3) — LAN Configuration Requirements diagram (page 17)
Fig. 8 · LAN Configuration Requirements

one for a parent and one for children. Only the parent’s login can be used to set up Parental Control and MAC Filtering. The child’s login can configure all other features of the gateway.

b. Log in to the gateway.

  • To log in as the parent, enter superuser for the user name and password for the password, both in lower case letters.
  • To log in as the child, enter admin for the user name and password for the password, both in lower case letters.

Connecting the Gateway to the Internet 1-7

Page 18 of the NETGEAR Cable Modem Router (CG814WG V3) user manual — LAN Configuration Requirements
Page 18 · click to enlarge
Page 18

When you connect to the gateway the Gateway status screen opens.

NETGEAR Cable Modem Router (CG814WG V3) — LAN Configuration Requirements diagram (page 18)
Fig. 9 · LAN Configuration Requirements
4. Enter your Network Configuration.
  • WAN IP Address: The IP Address that you would for your gateway in dotted decimal notation.
  • WAN Subnet Mask: The network number portion of an IP address. Unless you are implementing subnetting, use 255.255.0.0 as the subnet mask.
  • WAN Default Gateway: This is the ISP’s router to which your gateway will connect.
  • WAN Primary and Secondary DNS: A DNS server is a host on the Internet that translates Internet names (such as <a href="http://www.netgear.com" rel="nofollow noopener" target="_blank">www.netgear.com</a>) to numeric IP addresses. Typically your ISP transfers the IP address of one or two DNS servers to your gateway during login. If the ISP does not transfer an address, you must obtain it from the ISP and enter it manually here. If you enter an address here, you should reboot your PCs after configuring the gateway.
5. Click Apply to save your settings.

For more information about the Gateway Status screen see“Gateway Status” in Chapter 4.

1-8 Connecting the Gateway to the Internet

Page 19 of the NETGEAR Cable Modem Router (CG814WG V3) user manual — Chapter 2 Wireless Configuration
Page 19 · click to enlarge
Page 19

Chapter 2 Wireless Configuration

This chapter describes how to configure the wireless features of your CG814WG v3 Gateway. In planning your wireless network, you should consider the level of security required. You should also select the physical placement of your firewall in order to maximize the network speed.

gateway’s SSID, channel, or wireless security settings, you will lose your wireless connection when you click Apply. You must then change the wireless settings of your PC to match the gateway’s new settings.

Set up wireless features for the gateway in this order:

1. Install the gateway as described in Chapter 1, “Connecting the Gateway to the Internet” . The gateway should be working on your LAN before you set up the wireless features.
2. Plan the location for the gateway based on considerations in “Wireless Placement and Range Guidelines” on page 2-2 .
3. Use the form in section “SSID and Wireless Security Settings Form” on page 2-3 to keep track of your settings.
4. Enter the wireless settings, and verify wireless connectivity as described in “Viewing or Changing Wireless Settings” on page 2-4 .
5. Set up wireless security as described in “Turning on Access Control to Restrict Access by MAC Address” on page 2-6 , , or “How to Configure WPA” on page 2-10 .

For more information about wireless technology, see the link to “Wireless Communications” in Appendix B.

Page 20 of the NETGEAR Cable Modem Router (CG814WG V3) user manual — Wireless Placement and Range Guidelines
Page 20 · click to enlarge
Page 20

Wireless Placement and Range Guidelines

The range of your wireless connection can vary significantly based on the physical placement of the gateway. The latency, data throughput performance, and notebook power consumption of wireless adapters also vary depending on your configuration choices.

For best results, place your gateway:

  • Near the center of the area in which your PCs will operate.
  • In an elevated location such as a high shelf where the wirelessly connected PCs have line-ofsight access (even if through walls).
  • Away from sources of interference, such as PCs, microwave ovens, and 2.4 GHz cordless phones.
  • Away from large metal surfaces.
  • Put the antenna in a vertical position to provide the best side-to-side coverage. Put the antenna in a horizontal position to provide the best up-and-down coverage.
  • If using multiple access points, it is better if adjacent access points use different radio frequency channels to reduce interference. The recommended channel spacing between adjacent access points is 5 channels (for example, use channels 1 and 6, or 6 and 11).

The time it takes to establish a wireless connection can vary depending on both your security settings and placement. WEP connections can take slightly longer to establish. Also, WEP encryption can consume more battery power on a notebook computer.

2-2 Wireless Configuration

Page 21 of the NETGEAR Cable Modem Router (CG814WG V3) user manual — SSID and Wireless Security Settings Form
Page 21 · click to enlarge
Page 21

SSID and Wireless Security Settings Form

For a new wireless network, print or copy this form and fill in the settings. For an existing wireless network, the person who set up or is responsible for the network can get the settings. Be sure to set the Regulatory Domain correctly as the first step.

  • SSID . The Service Set Identification (SSID) identifies the wireless local area network. NETGEAR is the default SSID. However, you may customize it by using up to 32 alphanumeric characters. Write your customized SSID on the line below.

The SSID in the gateway is the SSID you configure in the wireless adapter card. All wireless nodes in the same network must be configured with the same SSID.

  • Authentication.

Circle one: Open System or Shared Key. Choose Shared Key for more security.

To use Shared Key, all devices in the network must be set to Shared Key and have the same keys in the same positions as those in the CG814WG v3.

  • WEP Encryption Keys. For all four keys, choose the Key Size. Circle one: 64, or 128 bits.
Key 1______________________________________________
Key 2______________________________________________
Key 3______________________________________________
Key 4______________________________________________
  • WPA-PSK (Pre-Shared Key) and WPA2-PSK . Record the WPA-PSK or WPA2-PSK key.
Key_____________________________________________ (8-63 characters)
  • WPA and WPA2 RADIUS Settings. For WPA and WPA2, record the following settings for the primary and secondary RADIUS servers.
Server Name/IP Address_____________________________________________
Port_____________________________________________
Shared Key_____________________________________________

Use the procedures described in the following sections to configure the CG814WG v3. Store this information in a safe place.

Wireless Configuration 2-3

Page 22 of the NETGEAR Cable Modem Router (CG814WG V3) user manual — Viewing or Changing Wireless Settings
Page 22 · click to enlarge
Page 22

Viewing or Changing Wireless Settings

You can view or change the wireless settings for the gateway. If you want to make changes, make sure to note the current settings first. See the “SSID and Wireless Security Settings Form” on page 2-3.

1. Log in to the gateway using its default address of http://192.168.0.1 or at whatever IP address the unit is currently configured Use the default user name of admin and default password of password , or whatever password you have set up.
2. Click the Wireless Settings link to go to the Wireless Settings screen.
NETGEAR Cable Modem Router (CG814WG V3) — Viewing or Changing Wireless Settings diagram (page 22)
Fig. 10 · Viewing or Changing Wireless Settings

2-4 Wireless Configuration

Page 23 of the NETGEAR Cable Modem Router (CG814WG V3) user manual — Viewing or Changing Wireless Settings
Page 23 · click to enlarge
Page 23

The settings in the Wireless Settings screen are explained in the following table.

Table 2-1. Wireless Settings

Wireless Network Name (SSID) The SSID is also known as the wireless network name. Enter a 32-character (maximum) name in this field. The characters are case sensitive. In a setting where there is more than one wireless network, different wireless network names provide a means for separating the traffic. Any device you want to participate in a wireless network must use the SSID.

Region The location where the gateway is used.

Channel The wireless channel used by the gateway. The default is channel 6. You should not need to change the wireless channel unless you experience interference (shown by lost connections and/or slow data transfers). Should this happen, you may need to experiment with different channels to see which is the best.

Enable Wireless Access Point On by default, you can also turn off the wireless radio

to disable access through this device. This can be helpful for configuration, network tuning, or troubleshooting activities.

Allow Broadcast Name (SSID) On by default, the gateway broadcasts its SSID,

allowing wireless stations which have a “null” (blank) SSID to adopt the correct SSID. The default SSID is NETGEAR. If you disable broadcast of the SSID, only devices that have the correct SSID can connect. This nullifies the wireless network “discovery” feature of some products such as Windows XP, but the data is still fully exposed to a determined snoop using specialized test equipment like wireless sniffers. For this reason NETGEAR recommends that you also enable wireless security.

Wireless Card Access List

Turn Access Control On Access control is disabled by default so that any computer that is configured with the correct SSID can connect. For information about access control, see “Turning on Access Control to Restrict Access by MAC Address” on page 2-6.

Settings Description · Wireless Access Point · Wireless Configuration 2-5

Page 24 of the NETGEAR Cable Modem Router (CG814WG V3) user manual — Turning on Access Control to Restrict Access by MAC Address
Page 24 · click to enlarge
Page 24

Table 2-1. Wireless Settings (continued)

Security Options Disable Wireless security is disabled by default. After the gateway is connected to the Internet, NETGEAR strongly recommends that you implement wireless security.

  • WEP (Wired Equivalent Privacy) 64-bit encryption
  • WEP (Wired Equivalent Privacy) 128-bit encryption

WEP security uses encryption keys. Wired Equivalent Privacy (WEP) data encryption provides data security. WEP Shared Key authentication and WEP data encryption will block all but the most determined eavesdropper. You can select 64-bit or 128-bit encryption. See “How to Configure WEP (Wired Equivalent Privacy)” on page 2-8.

WPA-PSK WPA2 WPA Enterprise

Wi-Fi Protected Access (WPA) data encryption provides data security. The very strong authentication along with dynamic per frame rekeying of WPA make it virtually impossible to compromise. Because this is a new standard, wireless device driver and software availability may be limited. WPA-PSK uses authentication from a Radius server. WPA2 uses a pre-shared key passphrase. See “How to Configure WPA” on page 2-10.

Turning on Access Control to Restrict Access by MAC Address

By default, any wireless PC that is configured with the correct SSID and WEP/WPA settings will be allowed access to your wireless network. For increased security, you can restrict access to the wireless network to only allow specific PCs based on their MAC addresses.

You can restrict access to only trusted PCs so that unknown PCs cannot wirelessly connect to the CG814WG v3 Gateway. MAC address filtering adds an obstacle against unwanted access to your network, but the data broadcast over the wireless link is fully exposed.

Settings Description · 2-6 Wireless Configuration

Page 25 of the NETGEAR Cable Modem Router (CG814WG V3) user manual — Turning on Access Control to Restrict Access by MAC Address
Page 25 · click to enlarge
Page 25

To restrict access based on MAC addresses:

1. Connect to the gateway and log in as described in “Viewing or Changing Wireless Settings” on page 2-4 .

your computer’s MAC address to the Access List. Otherwise you will lose your wireless connection when you click Apply. You must then access the gateway from a wired computer, or from a wireless computer that is on the access control list, to make any further changes.

2. Click Wireless Settings, and then select the Turn Access Control On check box.

When you enable access control, the access point only accepts connections from clients on the selected access control list. This provides an additional layer of security.

3. Click the Setup Access List button to display the Access List.
NETGEAR Cable Modem Router (CG814WG V3) — Turning on Access Control to Restrict Access by MAC Address diagram (page 25)
Fig. 11 · Turning on Access Control to Restrict Access by MAC…

The Access List displays a list of wireless clients that will have access to the wireless network when the list is enabled.

Wireless Configuration 2-7

Page 26 of the NETGEAR Cable Modem Router (CG814WG V3) user manual — How to Configure WEP (Wired Equivalent Privacy)
Page 26 · click to enlarge
Page 26
4. Adjust the list as needed for your network. You can add a devices to the Access List using either of the following methods:

a. If the computer is in the Connected Wireless Devices table, click the radio button of that computer to capture its MAC address; or

b. Specify the MAC address of the device to be added to the Access List in the Add Access Filter fields. The MAC address can usually be found on the bottom of the wireless device.

descriptive name for the computer that you are adding.

c. Click Add.

4. Click Apply to save these settings. Now, only devices on this list will be allowed to wirelessly connect to the gateway.

How to Configure WEP (Wired Equivalent Privacy)

disconnected when you click Apply. Reconfigure your wireless computer to match the new settings, or access the gateway from a wired computer to make further changes.

To configure WEP data encryption:

1. Log in to the gateway using its default address of http://192.168.0.1 or at whatever IP address the unit is currently configured. Use the default user name of admin and default password of password , or the password you have set up.
2. Click the Wireless Settings link to go to the Wireless Settings screen.
3. Depending on the encryption strength that you want, select one of these options:
  • WEP (Wired Equivalent Privacy) 64-bit encryption
  • WEP (Wired Equivalent Privacy) 128-bit encryption

2-8 Wireless Configuration

Page 27 of the NETGEAR Cable Modem Router (CG814WG V3) user manual — How to Configure WEP (Wired Equivalent Privacy)
Page 27 · click to enlarge
Page 27

Settings for WEP encryption are shown on the screen:

NETGEAR Cable Modem Router (CG814WG V3) — How to Configure WEP (Wired Equivalent Privacy) diagram (page 27)
Fig. 12 · How to Configure WEP (Wired Equivalent Privacy)
4. Select the Authentication. Choose Open System , Shared Key , or Open System or Shared Key . The default is Open System.
5. Enter the encryption settings:
  • WEP PassPhrase: To use a passphrase to generate the keys, enter a passphrase and click Generate. This automatically creates the keys. Wireless stations must use the passphrase or keys to access the gateway.
  • Key 1-Key4: You can manually enter the four data encryption keys. These values must be identical on all computers and access points in your network. Enter ten hexadecimal digits (any combination of 0-9, a-f, or A-F).
  • Select which of the four keys will be the default. Data transmissions are always encrypted using the default key. The other keys can only be used to decrypt received data. The four entries are disabled if WPA-PSK or WPA authentication is selected.
6. Click Apply to save your settings.

disconnected when you click Apply. Reconfigure your wireless adapter to match the new settings or access the gateway from a wired computer to make any further changes.

Wireless Configuration 2-9

Page 28 of the NETGEAR Cable Modem Router (CG814WG V3) user manual — How to Configure WPA
Page 28 · click to enlarge
Page 28

How to Configure WPA

the client. Windows XP and Windows 2000 with Service Pack 3 or above do include the client software that supports WPA. The wireless adapter hardware and driver must also support WPA. Consult the product documentation for your wireless adapter and WPA client software for instructions on configuring WPA settings.

To configure WPA in the gateway:

1. Log in to the gateway at the default LAN address of http://192.168.0.1 with the default user name of admin and default password of password , or using whatever LAN address and password you have set up.
2. Click Wireless Settings to go to the Wireless Settings screen.
3. Select WPA-PSK, WPA2-PSK, or WPA (Enterprise).

The settings shown on the screen depend on which Security Option you select.

WPA-PSK WPA2-PSK WPA (Enterprise)

NETGEAR Cable Modem Router (CG814WG V3) — How to Configure WPA diagram (page 28)
Fig. 13 · How to Configure WPA
NETGEAR Cable Modem Router (CG814WG V3) — How to Configure WPA diagram (page 28)
Fig. 14 · How to Configure WPA
NETGEAR Cable Modem Router (CG814WG V3) — How to Configure WPA diagram (page 28)
Fig. 15 · How to Configure WPA
4. For WPA-PSK or WPA2-PSK, enter the Passphrase. Click Apply to save your settings.
5. If you are using WPA (Enterprise) then enter the settings for the Radius Server. These settings are required for communication with the primary Radius server. A secondary Radius server can be configured, which is used on failure on Primary Radius Server.
  • Primary Radius Server IP Address : The IP address of the Radius Server. The default is 0.0.0.0

2-10 Wireless Configuration

Page 29 of the NETGEAR Cable Modem Router (CG814WG V3) user manual — How to Configure WPA
Page 29 · click to enlarge
Page 29
  • Radius Port : Port number of the Radius Server. The default is 1812.
  • Shared Key : This is shared between the Wireless Access Point and the Radius Server while authenticating the supplicant.
6. Click Apply to save your settings.

Wireless Configuration 2-11

Page 30 of the NETGEAR Cable Modem Router (CG814WG V3) user manual — How to Configure WPA
Page 30 · click to enlarge
Page 30

2-12 Wireless Configuration

Page 31 of the NETGEAR Cable Modem Router (CG814WG V3) user manual — Content Filtering
Page 31 · click to enlarge
Page 31

Chapter 3 Content Filtering and Firewall Rules

This chapter describes how to use Content Filtering and Firewall Rules for the CG814WG v3 Gateway to protect your network.

features.

Content Filtering

NETGEAR Cable Modem Router (CG814WG V3) — Content Filtering diagram (page 31)
Fig. 16 · Content Filtering

Content Filtering features include Logs, Block Sites, and Services. Firewall rules can also be used for content filtering.

Page 32 of the NETGEAR Cable Modem Router (CG814WG V3) user manual — Blocking Keywords, Sites, and Services
Page 32 · click to enlarge
Page 32

Logs

A log is a detailed record of the Denial of Service (DoS) attacks directed at your network. You can use e-mail notification to receive these logs in an e-mail message. If you do not have e-mail notification set up you can connect to the gateway to view the logs.

NETGEAR Cable Modem Router (CG814WG V3) — Logs diagram (page 32)
Fig. 17 · Logs

To receive logs by e-mail:

1. For the Contact Email Address, type an e-mail address to which the logs will be sent. Use a full e-mail address (for example, ChrisXY@myISP.com).
2. For the SMTP Server Name, type the outgoing SMTP mail server of your ISP (for example, mail.myISP.com). If you leave this box blank, no alerts or logs will be sent.
3. Select the E-mail Alerts Enable check box.
4. Click Apply .

For information about event logs, see “Event Log” in Chapter 4.

Blocking Keywords, Sites, and Services

  • The gateway provides a variety of options for blocking Internet based content and communications services. With its content filtering feature, the CG814WG v3 Gateway prevents objectionable content from reaching your PCs. The CG814WG v3 allows you to control access to Internet content by screening for keywords within Web addresses. It also has the capability to block access to all sites except those that are explicitly allowed. Key content filtering options include:
  • Blocking access from your LAN to Internet locations that contain keywords that your specify.
  • Blocking access to websites that you specify as off-limits.
  • Allowing access to only websites that you specify as allowed.

3-2 Content Filtering and Firewall Rules

Page 33 of the NETGEAR Cable Modem Router (CG814WG V3) user manual — Blocking Keywords and Domains
Page 33 · click to enlarge
Page 33

Blocking Keywords and Domains

The CG814WG v3 Gateway allows you to restrict access to Internet content based on functions such as Web address keywords and Web domains. A domain name is the name of a particular website. For example, for the address www.NETGEAR.com the domain name is NETGEAR.com.

To block keywords and domains:

1. Log in to the gateway at its default LAN address of http://192.168.0.1 with its parent default user name of superuser , default password of password , or using whatever password and LAN address you have chosen for the gateway in parent mode.
2. Click the Block Sites link under the Content Filtering heading.
NETGEAR Cable Modem Router (CG814WG V3) — Blocking Keywords and Domains diagram (page 33)
Fig. 18 · Blocking Keywords and Domains
3. To use Keyword Blocking, select the Keyword Blocking Enable check box and then you can enter up to eight keywords.
  • To enter a keyword, type it, and then click Add Keyword. The keyword will be shown in the Keyword List.
  • If the keyword “XXX” is specified, the URL <<a href="http://www.badstuff.com/xxx.html&gt;" rel="nofollow noopener" target="_blank">http://www.badstuff.com/xxx.html&gt;</a> is blocked.
  • If the keyword “.com” is specified, only websites with other domain suffixes (such as .edu or .gov) can be viewed.

Content Filtering and Firewall Rules 3-3

Page 34 of the NETGEAR Cable Modem Router (CG814WG V3) user manual — Services
Page 34 · click to enlarge
Page 34
  • Enter the keyword “.” to block all Internet browsing access.
4. You can use the Domain List to create a list of allowed domains, or to create a list of denied domains. Select the Domain Blocking Enable check box. Then you can add domains.
  • To add a domain, type the domain, and then click Add Domain. It is added to the Domain List.
  • To block access to the domains in the Domain List, select Deny Domains.

For example, if the domain “badstuff.com” is specified, the URL

  • To allow access to only the domains in the Domain List, select Allow Domains. If the domain “<a href="http://goodstuff.com" rel="nofollow noopener" target="_blank">goodstuff.com</a>” is specified, you will be able to access only sites on the goodstuff site.
5. Click Apply to save your settings.

Services

You can use the Services screen to control which services are enabled or disabled:

NETGEAR Cable Modem Router (CG814WG V3) — Services diagram (page 34)
Fig. 19 · Services

3-4 Content Filtering and Firewall Rules

Page 35 of the NETGEAR Cable Modem Router (CG814WG V3) user manual — Firewall Rules
Page 35 · click to enlarge
Page 35

To enable a service, select its check box. To disable a service, clear its check box. The following table describes the services.

Table 3-1. Services

Firewall Features When Firewall Features are enabled, the gateway will perform Stateful Packet Inspection (SPI) and protect against Denial of Service (DoS) attacks.

VPN Pass Through When VPN Pass through is enabled, IPSec and PPTP traffic will be forwarded. When it is disabled, this traffic will be blocked.

Web Features Filter Proxy

Block Fragmented IP Packets

Firewall Rules

  • A firewall has two default rules, one for inbound traffic (WAN to LAN) and one for outbound traffic.
  • Inbound Rules (Port Forwarding): These rules restrict access from outsiders. The default rule is to block all access from outside except responses to requests from the LAN side. You can use Port Forwarding to add predefined or custom rules to specify exceptions to the default rule.
  • Outbound Rules (Port Blocking): These rules control access to outside resources from local users.The default rule is to allow all access from the LAN side to the outside. You can use Port Blocking to add predefined or custom rules to specify exceptions to the default rules.

Content Filtering and Firewall Rules 3-5

Show 6 more labels / short text on this page
Settings Description · Multicast · Filter Cookies · Filter Java Applets · Filter ActiveX · Filter Popup Windows
Page 36 of the NETGEAR Cable Modem Router (CG814WG V3) user manual — Port Forwarding
Page 36 · click to enlarge
Page 36

The Firewall Rules screen is shown below:

NETGEAR Cable Modem Router (CG814WG V3) — Port Forwarding diagram (page 36)
Fig. 20 · Port Forwarding

Port Forwarding

With port forwarding, you can make local computers or servers available to the Internet for different services. For example, FTP uses TCP ports 20 and 21. The selections on this screen are:

  • Active Forwarding Rules: This table displays a list of ports that are currently forwarded.
  • Choose Predefined Service: Select a predefined service from the pull-down menu.
  • Add Custom Rules: You can set up a custom service that is not in the list of predefined services.
  • To access the local computer from the Internet, you must use the WAN address of your gateway, which can be found on the Basic Settings page.

Because the gateway uses Network Address Translation (NAT), your network presents only one IP address to the Internet, and outside users cannot directly address any of your local computers. However, by defining an inbound rule you can make a local server (for example, a web server or

3-6 Content Filtering and Firewall Rules

Page 37 of the NETGEAR Cable Modem Router (CG814WG V3) user manual — Port Blocking
Page 37 · click to enlarge
Page 37

game server) visible and available to the Internet. The rule tells the gateway to direct inbound traffic for a particular service to one local server based on the destination port number. This is also known as Port Forwarding.

processes (such as a Web or FTP server) from your location. Your ISP may periodically check for servers and may suspend your account if it discovers any active services at your location. If you are unsure, refer to the Acceptable Use Policy of your ISP.

Considerations for Port Forwarding

  • If the IP address of the local server PC is assigned by DHCP, it may change when the PC is rebooted. To avoid this, you can assign a static IP address to your server outside the range that is assigned by DHCP, but in the same subnet as the rest of your LAN. By default, the IP addresses in the range of 192.168.0.2 through 192.168.0.9 are reserved for this.
  • Local PCs must access the local server using the PCs’ local LAN address (192.168.0.XXX, by default). Attempts by local PCs to access the server using the external WAN IP address will fail.

Remember that allowing inbound services opens holes in your firewall. Only enable those ports that are necessary for your network. The following are two application examples of inbound rules.

Port Blocking

You can use this screen to block outbound traffic on specific ports.

the default rule.

  • Active Filters: This table displays a list of ports that are currently blocked.
  • Add Predefined Service: To block outbound traffic, select the service you would like to block from the drop-down list of predefined services. Click Add.
  • Add Custom Service: If the service you would like to block is not in the predefined list, you can add a custom service. Enter the range of ports you would like to block and select whether the ports are TCP, UDP or Both. Click Add.
  • To delete an existing rule, select its button on the left side of the table and click Delete.

Content Filtering and Firewall Rules 3-7

Page 38 of the NETGEAR Cable Modem Router (CG814WG V3) user manual — Port Blocking
Page 38 · click to enlarge
Page 38

3-8 Content Filtering and Firewall Rules

Page 39 of the NETGEAR Cable Modem Router (CG814WG V3) user manual — Maintenance
Page 39 · click to enlarge
Page 39

Chapter 4 Managing Your Network

This chapter describes how to perform network management tasks with your CG814WG v3 Gateway. When you log in to the gateway you will see these tasks grouped under the Maintenance heading and Advanced heading.

Firewall Rules”.

Log in to the gateway at its default LAN address of http://192.168.0.1 with its default User Name of admin, default password of password, or using whatever password and LAN address you have chosen for the gateway.

Maintenance

The CG814WG v3 Gateway Maintenance screens provide a variety of status and usage information.

NETGEAR Cable Modem Router (CG814WG V3) — Maintenance diagram (page 39)
Fig. 21 · Maintenance
Page 40 of the NETGEAR Cable Modem Router (CG814WG V3) user manual — Gateway Status
Page 40 · click to enlarge
Page 40

Gateway Status

Select Gateway Status to go to this screen:

NETGEAR Cable Modem Router (CG814WG V3) — Gateway Status diagram (page 40)
Fig. 22 · Gateway Status

The Gateway Status screen fields are explained in the following table.

Table 4-1. Gateway Status Fields

Information Standard Specification Compliant

The specification to which the gateway’s cable interface is compatible.

Hardware Version The hardware version of the gateway.

Software Version The software version of the gateway.

Cable Modem MAC Address The MAC address used by the cable modem port of the gateway. This MAC address may need to be registered with your Cable Service Provider.

Device MAC Address The MAC address of the router side of the gateway. This is the equivalent of your PC when connected to a cable modem. You can use the MAC Cloning feature to replace this MAC address with another address when sending packets to the WAN.

Cable Modem Serial Number The serial number of the gateway hardware.

CM Certificate If the Cable Modem certificate is Installed, it is possible for the service provider to upgrade your Data Over Cable service securely.

4-2 Managing Your Network

Field Description

Page 41 of the NETGEAR Cable Modem Router (CG814WG V3) user manual — Signal Status
Page 41 · click to enlarge
Page 41

Table 4-1. Gateway Status Fields (continued)

Status System Up Time This is the time since the gateway has registered with your cable service provider.

Network Access This field will change to Allowed when the registration with your cable service provider is complete.

Cable Modem IP Address The IP address of you gateway, as seen from the Internet.

Signal Status

You can use the Signal Status page to track your gateway’s initialization procedure, and to get details on the Downstream and Upstream cable channel. After the cable modem is initialized you can see the current time.

NETGEAR Cable Modem Router (CG814WG V3) — Signal Status diagram (page 41)
Fig. 23 · Signal Status

The gateway goes through the following steps to be provisioned

1. Acquire and lock Downstream Channel
2. Acquire upstream parameters and range.
3. Lock Upstream Channel
4. Acquire IP Address through DHCP

Managing Your Network 4-3

Field Description

Page 42 of the NETGEAR Cable Modem Router (CG814WG V3) user manual — Set Password
Page 42 · click to enlarge
Page 42

Set Password

For security reasons, the gateway has its own user name and password. Also, after a period of inactivity for a set length of time, the administrator login will automatically disconnect. When prompted, enter admin for the gateway user name and password for the gateway password. You can use procedures below to change the gateway's password and the amount of time for the administrator’s login timeout.

may use to log in to your Internet connection.

NETGEAR recommends that you change this password to a more secure password. The ideal password should contain no dictionary words from any language, and should be a mixture of both upper and lower case letters, numbers, and symbols. Your password can be up to 30 characters.

To change the password:

1. Log in to the gateway at its default LAN address of http://192.168.0.1 with its default User Name of admin , default password of password , or using whatever password and LAN address you have chosen for the gateway.
2. Select Set Password.
NETGEAR Cable Modem Router (CG814WG V3) — Set Password diagram (page 42)
Fig. 24 · Set Password
3. To change the password, first enter the old password, and then enter the new password twice.
4. Click Apply to save your changes.

configuration. If you have backed up the gateway settings previously, you should do a new backup so that the saved settings file includes the new password.

4-4 Managing Your Network

Page 43 of the NETGEAR Cable Modem Router (CG814WG V3) user manual — Backup Settings
Page 43 · click to enlarge
Page 43

Backup Settings

The configuration settings of the gateway are stored in a configuration file in the gateway. You can use the Backup Settings screen to work with the configuration file.

Click Backup to go to the Backup Settings screen:

NETGEAR Cable Modem Router (CG814WG V3) — Backup Settings diagram (page 43)
Fig. 25 · Backup Settings

You can save a copy of the current configuration settings, restore saved settings, or reset the gateway to the factory default settings.

turning off the gateway, or shutting down the computer.

To restore settings from a backup file:

1. Click Browse.
2. Locate and select the previously saved backup file (by default, CG814.cfg).
3. Click Restore.
  • A message notifies you when the gateway has been restored to previous settings.
  • The gateway restarts, which takes about one minute.

Managing Your Network 4-5

Restoring Saved Settings

Page 44 of the NETGEAR Cable Modem Router (CG814WG V3) user manual — Event Log
Page 44 · click to enlarge
Page 44

Resetting to Factory Default Settings

You can erase the gateway configuration and reset it to the factory default settings. The factory default settings are shown in See “Factory Default Settings” in Appendix A.

button on the rear panel of the gateway to restore the factory default settings.

On the Backup Settings screen, select Yes for Restore Factory Defaults and then click Apply.

The gateway reboots automatically. The gateway’s password will be password, the LAN IP address will be 192.168.0.1, and the gateway’s DHCP client will be enabled.

Event Log

The gateway logs security-related events such as denied incoming service requests and hacker probes. You can enable e-mail notification to receive these logs in an e-mail message.

NETGEAR Cable Modem Router (CG814WG V3) — Event Log diagram (page 44)
Fig. 26 · Event Log

For information about e-mail notifications, see “Logs” in Chapter 3.

4-6 Managing Your Network

Page 45 of the NETGEAR Cable Modem Router (CG814WG V3) user manual — WAN Setup
Page 45 · click to enlarge
Page 45

Advanced Settings

These features are for advanced users.

NETGEAR Cable Modem Router (CG814WG V3) — Advanced Settings diagram (page 45)
Fig. 27 · Advanced Settings

For Firewall Rules, see Chapter 3, “Content Filtering and Firewall Rules”.

WAN Setup

You can use this screen to set the gateway to respond to a Ping, specify a DMZ Address, and view or change the MTU Size setting.

NETGEAR Cable Modem Router (CG814WG V3) — WAN Setup diagram (page 45)
Fig. 28 · WAN Setup
  • Respond to Ping on WAN: If you want the gateway to respond to a Ping from the Internet, select this check box and then click Apply . This can be used as a diagnostic tool.
  • DMZ Address: Specifying a DMZ Address allows you to set up a PC that is available to anyone on the Internet for services that you have not defined. There are security issues with doing this, so only do this if you are willing to risk open access. If you do not assign a DMZ address, the gateway discards any undefined service request. — To assign a DMZ Address, type the value in the DMZ Address field and then click Apply . — To remove a DMZ Address, type 0 in the DMZ Address field, and then click Apply .

Managing Your Network 4-7

Page 46 of the NETGEAR Cable Modem Router (CG814WG V3) user manual — Dynamic DNS
Page 46 · click to enlarge
Page 46
  • MTU Size : The normal MTU (Maximum Transmit Unit) value for most Ethernet networks is 1500 Bytes. For some ISPs you may need to reduce the MTU. But this is rarely required, and should not be done unless you are sure it is necessary for your ISP connection.

Dynamic DNS

A Dynamic DNS Service provides a central public database where information (such as e-mail addresses, host names and IP addresses) can be stored and retrieved. The Dynamic DNS server also stores password-protected information and accepts queries based on e-mail addresses.

If you want to use a Dynamic DNS service, you must register for it. The Dynamic DNS client service provider will give you a password or key.

NETGEAR Cable Modem Router (CG814WG V3) — Dynamic DNS diagram (page 46)
Fig. 29 · Dynamic DNS

To set up Dynamic DNS:

1. Select the Use a Dynamic DNS Service check box if you have registered with a DDNS service provider.
2. Select the name of your dynamic DNS Service Provider.
3. Type the Host Name that your dynamic DNS service provider gave you.

The DDNS service provider may call this the domain name.

4. Type the User Name for your Dynamic DNS account.
5. Type the Password (or key) for your Dynamic DNS account.
6. If you have DYNDNS as your Dynamic DNS service provider, you can select the Use Wildcards check box to activate this feature.
7. Click Apply .

4-8 Managing Your Network

Page 47 of the NETGEAR Cable Modem Router (CG814WG V3) user manual — LAN IP Settings
Page 47 · click to enlarge
Page 47

LAN IP Settings

The LAN IP Setup screen allows configuration of LAN IP services such as the IP address of the gateway and DHCP.

NETGEAR Cable Modem Router (CG814WG V3) — LAN IP Settings diagram (page 47)
Fig. 30 · LAN IP Settings

You can use the LAN IP screen to configure your local area network. The DHCP and TCP/IP default values work in most cases.

  • LAN IP Address: The LAN IP Address that you would like to assign for your gateway in dotted decimal notation (factory default: 192.168.0.1).
  • Subnet Mask: The network number portion of an IP address. Unless you are implementing subnetting, use 255.255.255.0 as the subnet mask.
  • DHCP Server: The gateway is set up by default as a DHCP (Dynamic Host Configuration Protocol) server, which provides the TCP/IP configuration for all the computers that are connected to the gateway.
  • For more information about DHCP Server and DHCP Client Lease Info, see the online help.

Managing Your Network 4-9

Page 48 of the NETGEAR Cable Modem Router (CG814WG V3) user manual — Diagnostics
Page 48 · click to enlarge
Page 48

Diagnostics

You can use Diagnostics to test connectivity to PC using the Ping command, perform a DNS lookup, display the Routing Table and reboot the router. Click Diagnostics to go to this screen:

NETGEAR Cable Modem Router (CG814WG V3) — Diagnostics diagram (page 48)
Fig. 31 · Diagnostics

To perform a ping test:

1. For the Ping Target, enter the IP address of the computer that you would like to ping.
2. If you would like to specify additional details, you can set the Ping Size, No. of Ping and Ping Interval.
3. Click Start Test.
4. Click REFRESH to see the results of the Ping test.

Perform a DNS Lookup

A DNS (Domain Name Server) converts the Internet name (e.g. www.netgear.com) to an IP address. If you need the IP address of a Web, FTP, Mail or other Server on the Internet, you can do a DNS lookup to find the IP address.

4-10 Managing Your Network

Ping Test

Page 49 of the NETGEAR Cable Modem Router (CG814WG V3) user manual — Remote Management Access
Page 49 · click to enlarge
Page 49

Display the Routing Table

This operation will display the internal routing table. This information is used by Technical Support and other staff who understand Routing Tables.

Use this button to perform a remote reboot (restart). You can use this if the Router seems to have become unstable or is not operating normally.

router. However, connections to the Internet will automatically be re-established when possible.

Remote Management Access

With Remote Management, you can allow a user or users on the Internet to configure, upgrade and check the status of your CG814WG v3 Gateway.

To configure your gateway for Remote Management:

1. Click Remote Management to go to this screen:
NETGEAR Cable Modem Router (CG814WG V3) — Remote Management Access diagram (page 49)
Fig. 32 · Remote Management Access
2. Select the Allow Remote Management check box.
3. Specify the port number that will be used for accessing the management interface.

Managing Your Network 4-11

Reboot the Router

Page 50 of the NETGEAR Cable Modem Router (CG814WG V3) user manual — UPnP
Page 50 · click to enlarge
Page 50

Web browser access normally uses the standard HTTP service port 80. For greater security, you can change the remote management Web interface to a custom port by entering that number in the box provided. Choose a number between 1024 and 65535, but do not use the number of any common service port. The default is 8080, which is a common alternate for HTTP.

4. Click Apply to have your changes take effect.

Revert to Factory Default Setting

If you would like to erase settings but continue to allow access from the WAN after the settings have been erased, then select the Allow Remote Management after Factory Default Reset check box. Then click Erase.

URL to Connect to This Device

To manage this gateway via the Internet, you need to its public IP Address, as seen from the Internet. This public IP Address is allocated by your ISP, and is shown on this screen. But if your ISP account uses a dynamic IP Address, the address can change each time you connect to your ISP. There are two solutions to this problem:

  • Have your ISP allocate you a Fixed IP address.
  • Use the Dynamic DNS feature so you can connect using a domain name, rather than an IP address. See “Dynamic DNS” on page 4-8 .

UPnP

Universal Plug and Play (UPnP) helps devices, such as Internet appliances and computers, access the network and connect to other devices as needed. UPnP devices can automatically discover the services from other registered UPnP devices on the network.

NETGEAR Cable Modem Router (CG814WG V3) — UPnP diagram (page 50)
Fig. 33 · UPnP

4-12 Managing Your Network

Page 51 of the NETGEAR Cable Modem Router (CG814WG V3) user manual — UPnP
Page 51 · click to enlarge
Page 51
  • Turn UPnP On: The default setting is disabled. With this setting the router will not allow any device to automatically control the resources, such as port forwarding, of the router.
  • Advertisement Period: How often the gateway advertises (broadcasts) its UPnP information. The default is 30 minutes.
  • Advertisement Time to Live: The time to live for the advertisement is measured in hops (steps) for each UPnP packet sent.

For more information, see the online help.

Managing Your Network 4-13

Page 52 of the NETGEAR Cable Modem Router (CG814WG V3) user manual — UPnP
Page 52 · click to enlarge
Page 52

4-14 Managing Your Network

Page 53 of the NETGEAR Cable Modem Router (CG814WG V3) user manual — Basic Functions
Page 53 · click to enlarge
Page 53

Chapter 5 Troubleshooting

This chapter gives information about troubleshooting your CG814WG v3 Wireless Cable Modem Gateway. For the common problems listed, go to the section indicated.

  • Have I connected the gateway correctly?

Go to “Basic Functions” on page 5-1.

  • I cannot access the gateway configuration with my browser.

Go to “Connecting to the Gateway’s Main Menu” on page 5-2.

  • I have configured the gateway but I cannot access the Internet.

Go to “Troubleshooting the ISP Connection” on page 5-3.

  • I cannot remember the gateway’s configuration password or I want to clear the configuration and start over again.

Go to “Backup Settings” in Chapter 4.

Basic Functions

After you turn on power to the gateway, the following sequence of events should occur:

1. When power is first applied, verify that the Power LED is on.
2. Verify that the numbered Ethernet LEDs come on momentarily.
3. After approximately 30 seconds, verify that:
  • The Local port Link LEDs are lit for any local ports that are connected.
  • The Internet Link port LED is lit.

If any of these conditions does not occur, refer to the appropriate following section.

Page 54 of the NETGEAR Cable Modem Router (CG814WG V3) user manual — Connecting to the Gateway’s Main Menu
Page 54 · click to enlarge
Page 54

Using LEDs to Troubleshoot

The following table provides help when using the LEDs for troubleshooting.

Table 5-1. Using LEDs to Troubleshoot

All LEDS are off when the gateway is plugged in.

Make sure that the power cord is properly connected to your gateway and that the power supply adapter is properly connected to a functioning power outlet. Check that you are using the 12VDC power adapter supplied by NETGEAR for this product. If the error persists, you have a hardware problem and should contact technical support.

  • All LEDs Stay On
  • Clear the gateway’s configuration to factory defaults. This will set the gateway’s IP address to 192.168.0.1. See “Backup Settings” in Chapter 4 .
  • If the error persists, you might have a hardware problem and should contact technical support.

LAN LED is off for a port with an Ethernet connection.

  • Make sure that the Ethernet cable connections are secure at the gateway and at the hub or PC.
  • Make sure that power is turned on to the connected hub or PC.
  • Be sure you are using the correct cable:
  • When connecting the gateway’s Internet port to a cable or DSL modem, use the cable that was supplied with the cable or DSL modem. This cable could be a standard straight-through Ethernet cable or an Ethernet crossover cable.

Cable Link LED is off and the gateway is connected to the cable television cable.

  • Make sure that the coaxial cable connections are secure at the gateway and at the wall jack.
  • Make sure that your cable internet service has been provisioned by your cable service provider. Your provider should verify that the signal quality is good enough for cable modem service.
  • Remove any excessive splitters you may have on your cable line. It may be necessary to run a “home run” back to the point where the cable enters your home.

Connecting to the Gateway’s Main Menu

If you are unable to access the gateway’s main menu from a computer on your local network, check the following:

  • Check the Ethernet connection between the computer and the gateway as described in the previous section.

LED Behavior Action · 5-2 Troubleshooting

Page 55 of the NETGEAR Cable Modem Router (CG814WG V3) user manual — Troubleshooting the ISP Connection
Page 55 · click to enlarge
Page 55
  • Make sure that your PC’s IP address is on the same subnet as the gateway. If you are using the recommended addressing scheme, your PC’s address should be in the range of 192.168.0.10 to 192.168.0.254. Refer to the link to the online document “Internet Networking and TCP/IP Addressing” on page B-1 for help configuring your computer.

Recent versions of Windows and MacOS will generate and assign an IP address if the computer cannot reach a DHCP server. These auto-generated addresses are in the range of 169.254.x.x. If your IP address is in this range, check the connection from the PC to the gateway and reboot your PC.

  • If your gateway’s IP address has been changed and you don’t know the current IP address, clear the gateway’s configuration to factory defaults. This will set the gateway’s IP address to 192.168.0.1. This procedure is explained in “Diagnostics” on page 4-10 .
  • Make sure your browser has Java, JavaScript, or ActiveX enabled. If you are using Internet Explorer, click Refresh to be sure the Java applet is loaded.
  • Try quitting the browser and launching it again.
  • Make sure you are using the correct login information. The factory default login name is admin and the password is password . Make sure that CAPS LOCK is off when entering this information.

If the gateway does not save changes you have made in the Web Configuration Interface, check the following:

  • When entering configuration settings, be sure to click the APPLY button before moving to another menu or tab, or your changes are lost.
  • Click the Refresh or Reload button in the Web browser. The changes may have occurred, but the Web browser may be caching the old configuration.

Troubleshooting the ISP Connection

If your gateway is unable to access the Internet and your Cable Link LED is on, you may need to register the Cable MAC Address and/or Device MAC Address of you gateway with your cable service provider. This is described in “Connecting the CG814WG v3 Gateway” on page 1-4.

Additionally, your PC may not have the gateway configured as its TCP/IP gateway. If your PC obtains its information from the gateway by DHCP, reboot the PC and verify the gateway address. See the link to the online document “Internet Networking and TCP/IP Addressing” on page B-1

Troubleshooting 5-3

Page 56 of the NETGEAR Cable Modem Router (CG814WG V3) user manual — Testing the LAN Path to Your Gateway
Page 56 · click to enlarge
Page 56

Troubleshooting a TCP/IP Network Using a Ping Utility

Most TCP/IP terminal devices and routers contain a ping utility that sends an echo request packet to the designated device. The device then responds with an echo reply. Troubleshooting a TCP/IP network is made easier by using the ping utility in your PC or workstation.

Testing the LAN Path to Your Gateway

You can use ping to verify that the LAN path to your gateway is set up correctly.

To ping the gateway from a PC running Windows 95 or later:

1. From the Windows toolbar, click on the Start button and select Run.
2. In the field provided, type Ping followed by the IP address of the gateway, as in this example:

ping 192.168.0.1

3. Click OK.

You should see a message like this one:

Pinging with 32 bytes of data

If the path is working, you see this message:

Reply from < IP address >: bytes=32 time=NN ms TTL=xxx

If the path is not working, you see this message:

If the path is not working correctly, you could have one of the following problems:

  • Wrong physical connections.

– Make sure the LAN port LED is on. If the LED is off, see “Using LEDs to Troubleshoot” on page 5-2.

– Check that the corresponding Link LEDs are on for your network interface card and for the hub ports (if any) that are connected to your workstation and gateway.

  • Wrong network configuration.

– Verify that the Ethernet card driver software and TCP/IP software are both installed and configured on your PC or workstation.

– Verify that the IP address for your gateway and your workstation are correct and that the addresses are on the same subnet.

Request timed out · 5-4 Troubleshooting

Page 57 of the NETGEAR Cable Modem Router (CG814WG V3) user manual — Testing the Path from Your PC to a Remote Device
Page 57 · click to enlarge
Page 57

Testing the Path from Your PC to a Remote Device

After verifying that the LAN path works correctly, test the path from your PC to a remote device. From the Windows run menu, type:

PING -n 10

where is the IP address of a remote device such as your ISP’s DNS server.

If the path is functioning correctly, replies as in the previous section are displayed. If you do not receive replies:

  • Check that your PC has the IP address of your gateway listed as the default gateway. If the IP configuration of your PC is assigned by DHCP, this information will not be visible in your PC’s Network Control Panel. Verify that the IP address of the gateway is listed as the default gateway. See the link to the online document “Internet Networking and TCP/IP Addressing” on page B-1 .
  • Check to see that the network address of your PC (the portion of the IP address specified by the netmask) is different from the network address of the remote device.
  • Check that your Cable Link LED is on.
  • If your ISP assigned a host name to your PC, enter that host name as the Account Name in the Basic Settings menu.

Troubleshooting 5-5

Page 58 of the NETGEAR Cable Modem Router (CG814WG V3) user manual — Testing the Path from Your PC to a Remote Device
Page 58 · click to enlarge
Page 58

5-6 Troubleshooting

Page 59 of the NETGEAR Cable Modem Router (CG814WG V3) user manual — Technical Specifications
Page 59 · click to enlarge
Page 59

Appendix A Technical Specifications and Factory Default

Settings

This appendix provides technical specifications and default factory settings for the CG814WG v3 Gateway.

Technical Specifications

Network Protocol and Standards Compatibility

  • Data and Routing Protocols:
  • TCP/IP
  • DHCP server and client
  • DNS relay
  • NAT (many-to-one)
  • TFTP client
  • VPN pass through (IPSec, PPTP)
  • Power Adapter
  • North America (input): 120V, 60 Hz, input
  • All regions (output): 12 V DC @ 1.25A output, 15W maximum
  • Physical Specifications
  • Dimensions: 175 by 114 by 30 mm ( 6.9 by 4.5 by 1.2 in.)
  • Weight: 0.31 kg (0.68 lb)
  • Operating temperature: 32 ° -140 ° F (0 ° to 40 ° C)
  • Operating humidity: 90% maximum relative humidity, noncondensing.

Electromagnetic Emissions Meets requirements of FCC Part 15 Class B

LAN10BASE-T or 100BASE-Tx, RJ-45 USB 1.1 Function 802.11g and 802.11b Wireless Access Point

WAN DOCSIS 2.0. Downward compatible with DOCSIS 1.0 and DOCSIS 1.1.

Technical Specifications and Factory Default Settings A-1

Show 4 more labels / short text on this page
Specification Description · Environmental Specifications · Interface Specifications · Wireless
Page 60 of the NETGEAR Cable Modem Router (CG814WG V3) user manual — Factory Default Settings
Page 60 · click to enlarge
Page 60

Radio Data Rates 1, 2, 5.5, 6, 9, 12, 18, 24, 36, 48, 54, and 108 Mbps Auto Rate Sensing

Frequency 2.4-2.5 GHz

Operating Frequency Ranges2.412~2.462 GHz (US) 2.412~2.472 GHz (Japan) 2.412~2.472 GHz (Europe ETSI)
Encryption40-bit (also called 64-bit), 128-bit WEP data encryption, WPA-PSK(TKIP), and WPA2-PSK(AES)

Factory Default Settings

You can use the reset button located on the rear panel of your gateway to reset all settings to their factory defaults. This is called a hard reset. To perform a hard reset, push and hold the reset button for 5 seconds. The gateway will reboot and return to the settings shown in the following table.

Table A-1. Default Configuration Settings

User login URL http://192.168.1.1

User name (case sensitive) admin superuser

Login Password (case sensitive) password

Lan IP 192.168.1.1

Subnet Mask 255.255.255.0

DHCP starting IP address 192.168.1.2

DHCP Ending IP Address 192.168.1.254

DMZ Enabled or disabled

A-2 Technical Specifications and Factory Default Settings

Show 9 more labels / short text on this page
Specification Description · Feature Default Behavior · Gateway Login · Local Network (LAN) · RIP direction None · RIP version Disabled · RIP authentication None · DHCP server Enabled · Time zone GMT
Page 61 of the NETGEAR Cable Modem Router (CG814WG V3) user manual — Factory Default Settings
Page 61 · click to enlarge
Page 61

Table A-1. Default Configuration Settings

Time Zone Adjusted for Daylight Saving Time

Technical Specifications and Factory Default Settings A-3

Feature Default Behavior · Disabled · SNMP Disabled

Page 62 of the NETGEAR Cable Modem Router (CG814WG V3) user manual — Factory Default Settings
Page 62 · click to enlarge
Page 62

Table A-1. Default Configuration Settings

Inbound (communications coming in from the Internet)

Disabled (except traffic on port 80, the http port)

Outbound (communications going out to the Internet)

Source MAC filtering Disabled

WAN MAC address Use default hardware address

WAN MTU size 1500

Transmission Speed Autoa

Country/Region United States (varies by region)

RF Channel 6 until the region is selected

Operating Mode g and b until the region is selected

Authentication Type Open System

Wireless Card Access List All wireless stations allowed

a. Maximum Wireless signal rate derived from IEEE Standard 802.11 specifications. Actual throughput will

vary. Network conditions and environmental factors, including volume of network traffic, building materials and construction, and network overhead, lower actual data throughput rate.

A-4 Technical Specifications and Factory Default Settings

Show 12 more labels / short text on this page
Feature Default Behavior · Firewall · Enabled (all) · Internet Connection · Wireless · Wireless Communication Disabled · SSID Name NETGEAR · Security Disabled · Broadcast SSID Enabled · Data Rate Best · Output Power Full · Access Point Enabled
Page 63 of the NETGEAR Cable Modem Router (CG814WG V3) user manual — B-1
Page 63 · click to enlarge
Page 63

Appendix B Related Documents

This appendix provides links to reference documents you can use to gain a more complete understanding of the technologies used in your NETGEAR product.

Windows XP and Vista Wireless Configuration Utilities

http://documentation.netgear.com/reference/enu/winzerocfg/index.htm

Internet Networking and TCP/IP Addressing

http://documentation.netgear.com/reference/enu/tcpip/index.htm

Wireless Communications http://documentation.netgear.com/reference/enu/wireless/index.htm

Preparing a Computer for Network Access

http://documentation.netgear.com/reference/enu/wsdhcp/index.htm

Virtual Private Networking (VPN) http://documentation.netgear.com/reference/enu/vpn/index.htm

Glossary http://documentation.netgear.com/reference/enu/glossary/index.htm

B-1

Document Link

Page 64 of the NETGEAR Cable Modem Router (CG814WG V3) user manual — Appendix B Related Documents
Page 64 · click to enlarge
Page 64

B-2 Related Documents

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the NETGEAR Cable Modem Router (CG814WG V3)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the NETGEAR Cable Modem Router (CG814WG V3)

Be the first to ask — other owners or our team will answer.

Original document

NETGEAR Cable Modem Router (CG814WG V3) manual PDF

64 pages·1.1 MB·Modem·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…